[See subsections ...]
Search Results "Changes in Level"
Commonly Searched Documents
-
303 Changes in Level
-
11B-403.4 Changes in level
Changes in level shall comply with Section 11B-303....
-
11B-403.4 Changes in level
Changes in level shall comply with Section 11B-303....
-
11B-403.4 Changes in level
Changes in level shall comply with Section 11B-303....
-
Changes in Level [§303]
Changes in Level [§303] Changes in level can be up to ¼” without treatment or ½” if beveled with a slope no steeper than 1:2....
-
11B-303 CHANGES IN LEVEL
[See subsections ...]
-
11B-303 Changes in level.
[See subsections ...]
-
11B-303 Changes in level
[See subsections ...]
-
11B-404.2.5 Thresholds
Raised thresholds and changes in level at doorways shall comply with Sections 11B-302 and 11B-303. Exception: Reserved....
-
SECTION 1131A CHANGES IN LEVEL ON ACCESSIBLE ROUTES
[See subsections ...]
-
SECTION 1131A CHANGES IN LEVEL ON ACCESSIBLE ROUTES
[See subsections ...]
-
General: ADA Standard Section 303.1
Section 303.1 of the ADA Standards covers information in the current ADA Standards for changes in level for floor and ground surfaces.
-
11B-405.7.1 Slope
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved....
-
Thresholds: ADA Standard Section 404.2.5
Section 404.2.5 covers the current ADA Standards for thresholds at doors.
-
11B-813.2.1.2 Clearance
A 36 inches minimum (914 mm) width side clearance shall be provided along the entire length of one side of adult changing tables....
-
Floor or Ground Surfaces: ADA Standard Section 405.4
Section 405.4 covers the current ADA Standards for the floor or ground surfaces of ramps.
-
Changes in Level [4.5.2]
Vertical changes in level up to ¼ inch are permitted without treatment along accessible routes. Changes in level ¼ to ½ inch must be beveled with a slope no greater than 1:2....
-
C1-4. Accessible Route Level Changes
Is the accessible route free of steps and abrupt level changes over 1/2 inch? Note: Level changes between 1/4 inch and 1/2 inch should be beveled. Yes _____ No _____...
-
Ground Level Play Components: ADA Standard Section 240.2.1
Section 240.2.1 covers scoping requirements in the current ADA Standards for ground level play components.
-
Thresholds: ADA Standard Section 404.3.3
Section 404.3.3 covers the current ADA Standards for thresholds at automatic and power-assisted doors and gates.
-
11B-404.3.3 Thresholds
Thresholds and changes in level at doorways shall comply with Section 11B-404.2.5....
-
303.3 Beveled
A change in level of ½ inch (13 mm) is permitted to be ¼ inch (6.4 mm) vertical plus ¼ inch (6.4 mm) beveled....
-
11B-303.3 Beveled
A change in level of ½ inch (13 mm) is permitted to be ¼ inch (6.4 mm) vertical plus ¼ inch (6.4 mm) beveled....
-
303.3 Beveled
A change in level of 1/2 inch (13 mm) is permitted to be ¼ inch (6.4 mm) vertical plus ¼ inch (6.4 mm) beveled....