The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8, when measured on level ground, for a maximum rise of 3 inches, and the transition from station...
Search Results "Changes in Level"
-
§ 38.125(b)(8) Platform entrance ramp
-
§ 38.125(c)(3) Ramp threshold
Changes in level between 1/4 inch and 1/2 inch shall be beveled with a slope no greater than 1:2....
-
§ 38.159(b)(8) Platform entrance ramp
The entrance ramp, or loading-edge barrier used as a ramp, shall not exceed a slope of 1:8, measured on level ground, for a maximum rise of 3 inches (75 mm), and the transition from roadway...
-
§ 38.159(c)(3) Ramp threshold
Changes in level between 1/4 inch (6.5 mm) and 1/2 inch (13 mm) shall be beveled with a slope no greater than 1:2....
-
502.4 Floor or Ground Surfaces
Access aisles shall be at the same level as the parking spaces they serve. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted. ...
-
Attachment I: Program Access in Existing Facilities
Attachment I: Program Access in Existing Facilities
-
Accessible Routes
The accessible route must comply with ADAAG provisions for the location, width (minimum of 36 inches), passing space, head room, surface, slope (maximum of 1:12 or 8.33%), changes in level...
-
Features of Accessible Parking Spaces
Access aisle width is at least 60 inches, must be at the same level and the same length as the adjacent parking space(s) it serves, maximum slope in all directions is 1:48, and access aisle...
-
3) Where the standard says "Changes in level are not permitted", but no advisory follows the standard
3) Where the standard says "Changes in level are not permitted", but no advisory follows the standard, such as 404.2.4.4 floor or ground surfaces at doors: Although the Advisory at 304.2...
-
303 Changes in Level
-
303.1 General
Where changes in level are permitted in floor or ground surfaces, they shall comply with 303. EXCEPTIONS: 1....
-
303.2 Vertical
Changes in level of 1/4 inch (6.4 mm) high maximum shall be permitted to be vertical....
-
M303.3 Entry
Where there is a change in level at the entry to wheelchair spaces, the change in level shall comply with M303.3....
-
M303.3 Entry
Where there is a change in level at the entry to a wheelchair space, the change in level shall comply with M303.3....
-
303.3 Beveled
Changes in level between 1/4 inch (6.4 mm) high minimum and 1/2 inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2. Advisory 303.3 Beveled....
-
M303.3.1 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical....
-
M303.3.1 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical....
-
M303.3.2 Beveled
Changes in level between ¼ inch (6.4 mm) high and ½ inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2....
-
M303.3.2 Beveled
Changes in level between ¼ inch (6.4 mm) high and ½ inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2....
-
M303.3.3 Ramped
Changes in level greater than ½ inch (13 mm) high shall be ramped and shall comply with M303.3.3....
-
M303.3.3 Ramped
Changes in level greater than ½ inch (13 mm) high shall be ramped and shall comply with M303.3.3....
-
303.4 Ramps
Changes in level greater than 1/2 inch (13 mm) high shall be ramped, and shall comply with 405 or 406....
-
203.9 Employee Work Areas
203.9 Employee Work Areas. Spaces and elements within employee work areas shall only be required to comply with 206.2.8, 207.1, and 215.3 and shall be designed and constructed so...
-
A. Changes in Level
Abrupt Level Changes - Are hallways and corridors free of any steps or abrupt vertical level changes over 1/4" that will impede access for persons who use wheelchairs, walkers, and other...