This data depicts the amount of clear floor area required by persons using wheeled mobility devices when performing a forward or side reach to a target location (e.g., reaching to a...
Search Results "Floor Slope"
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Manual Wheelchair
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Power Chair
This data depicts the amount of clear floor area required by persons using wheeled mobility devices when performing a forward or side reach to a target location (e.g., reaching to a...
-
11B-206.4.1 Entrances and exterior ground floor exits
All entrances and exterior ground-floor exits to buildings and facilities shall comply with Section 11B-404. [2010 ADAS] 206.4.1 Public Entrances. ...
-
11B-206.4.1 Entrances and exterior ground floor exits
All entrances and exterior ground-floor exits to buildings and facilities shall comply with Section 11B-404. [2010 ADAS] 206.4.1 Public Entrances. ...
-
11B-206.4.1 Entrances and exterior ground floor exits
All entrances and exterior ground-floor exits to buildings and facilities shall comply with Section 11B-404. [2010 ADA Standards] 206.4.1 Public Entrances....
-
Load and Unload Areas
Load and Unload Areas The floor or ground surface in the load and unload areas must have a slope not steeper than 1:48 and be stable, firm, and slip resistant....
-
Sleeping Areas: ADA Standard Section 806.2.3
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
Clear Floor Space [4.25.2] and Height [4.25.3]
Clear Floor Space [4.25.2] and Height [4.25.3] Clear floor space for either a forward or side approach is allowed....
-
4. Assess During the Planning, Installation and Maintenance Phases
A digital level can be used to measure the running slope and cross slope....
-
1005.4 Clear Floor or Ground Space
At each location where there are railings, guards, or handrails complying with 1005.2.1, a clear floor or ground space complying with 305 shall be provided....
-
1005.4 Clear Floor or Ground Space
At each location where there are railings, guards, or handrails complying with 1005.2.1, a clear floor or ground space complying with 305 shall be provided....
-
Clear Floor Space [4.2.4]
Clearances are measured in relation to the usable clear floor space, not necessarily to the vertical support....
-
4.3.2 Clear Floor or Ground Space
Tent pads and tent platforms shall have clear floor or ground space surrounding the tent that is at least 48 inches (1220 mm) wide. This space shall not overlap the ORAR....
-
808.3 Clear Floor Space
Each jury box and witness stand shall have, within its defined area, clear floor space complying with 305....
-
808.3 Clear Floor Space
Each jury box and witness stand shall have, within its defined area, clear floor space complying with 305....
-
1009.1 General
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with 1009....
-
1009.1 General
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with 1009....
-
11B-407.2.1.3 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided at call controls. [2010 ADAS] Advisory 407.2.1.3 Clear Floor or Ground Space. ...
-
11B-407.2.1.3 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided at call controls. [2010 ADAS] Advisory 407.2.1.3 Clear Floor or Ground Space....
-
11B-407.2.1.3 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided at call controls. Advisory 11B-407.2.1.3 Clear floor or ground space....
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
11B-806.2.3 Sleeping areas
At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
11B-1009.1 General
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with Section 11B-1009....
-
1009.1 General
Where provided, pool lifts, sloped entries, transfer walls, transfer systems, and pool stairs shall comply with 1009....