Transfer platforms shall have level surfaces 14 inches (355 mm) deep minimum and 24 inches (610 mm) wide minimum.
Search Results "Elevator Building"
-
Size: ADA Standard Section 1008.3.1.1
-
Height: ADA Standard Section 1008.3.1.2
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface.
-
11B-411.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-411.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
11B-411.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-411.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
11B-411.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-411.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
- CalCasp Training: 2016 California Building Code Chapter 11A
-
Changes in Level within a Dwelling Unit
buildings be equipped with internal elevators, chair lifts, or other means of access to the upper levels (55 FR 24377)....
-
11B-407.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-407.3.
-
11B-407.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-407.3.
-
11B-407.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-407.3.
-
408.4.1 Car Dimensions and Doors
Elevator cars shall provide a clear width 42 inches (1065 mm) minimum and a clear depth 54 inches (1370 mm) minimum....
-
407.2.3.2 Car Designations
Destination-oriented elevators shall provide tactile car identification complying with 703.2 on both jambs of the hoistway immediately below the floor designation....
-
11B-407.4.10 Support rail
Support rails in elevator cabs are used in a different way than handrails along a walking surface such as a ramp or stairway. ...
-
11B-407.4.10 Support rail
Support rails in elevator cabs are used in a different way than handrails along a walking surface such as a ramp or stairway....
-
407.2.3.2 Car Designations
Destination-oriented elevators shall provide tactile car identification complying with 703.2 on both jambs of the hoistway immediately below the floor designation....
-
1.9.1.1.2
1.9.1.1.2 All buildings, structures and facilities that are leased, rented, contracted, sublet or hired by any municipal, county or state division of government, or by a special district...
-
1.9.1.1.2
1.9.1.1.2 All buildings, structures and facilities that are leased, rented, contracted, sublet or hired by any municipal, county or state division of government, or by a special district...
-
1011.5 Fire Rings, Grills, Fireplaces, and Wood Stoves
This section requires fire building surfaces to be 9 inches minimum above the ground, and cooking surfaces to be 15 inches minimum and 34 inches maximum above the ground....
-
11B-411.2.1.5 Button requirements
Keypad buttons, the accessibility function button, and additional hall call console buttons shall comply with Section 11B-411.2.1.5.
-
11B-411.2.1.5 Button requirements
Keypad buttons, the accessibility function button, and additional hall call console buttons shall comply with Section 11B-411.2.1.5.
-
Required Compliance [§206.6]
Only passenger elevators as classified by the referenced elevator safety code (ASME A17.1) can be used to meet the ADA Standards....
-
4.10.4 Hall Lanterns
A visible and audible signal shall be provided at each hoistway entrance to indicate which car is answering a call. Audible signals shall sound once for the up direction and twice...
-
4.10.12* Car Controls
Elevator control panels shall have the following features:...
-
4.10.12* CAR CONTROLS
Elevator control panels shall have the following features:...