Emergency communication shall comply with Section 11B-407.4.9.
Search Results "Elevator Building"
-
11B-411.4.9 Emergency communication
-
11B-407.4.7.1.5 Button spacing
A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons.
-
11B-411.4.10 Support rail
Support rails complying with Section 11B-407.4.10 shall be provided on at least one wall of the car.
-
11B-1008.3.1.1 Size
Transfer platforms shall have level surfaces 14 inches (356 mm) deep minimum and 24 inches (610 mm) wide minimum.
-
11B-411.4.10 Support rail
Support rails complying with Section 11B-407.4.10 shall be provided on at least one wall of the car.
-
11B-411.4.9 Emergency communication
Emergency communication shall comply with Section 11B-407.4.9.
-
11B-1008.3.2.1 Size
Transfer steps shall have level surfaces 14 inches (356 mm) deep minimum and 24 inches (610 mm) wide minimum.
-
11B-407.4.7.1.1 Type
Control buttons shall be identified by raised characters or symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section...
-
11B-1008.3.2.2 Height
Each transfer step shall be 8 inches (203 mm) high maximum.
-
11B-411.4.8.2 Audible indicators
Audible indicators shall comply with Section 11B-411.4.8.2.
-
11B-411.4.6.2 Buttons
Car control buttons shall comply with Sections 11B-407.4.6.2.1 and 11B-407.4.6.2.4. The car shall not have non-functional, exposed floor buttons.
-
11B-411.4.3 Platform to hoistway clearance
Platform to hoistway clearance shall comply with Section 11B-407.4.3.
-
11B-407.4.4 Leveling
Each car shall be equipped with a self-leveling feature that will automatically bring and maintain the car at floor landings within a tolerance of ½ inch (12.7 mm) under rated...
-
11B-409.4.7 Emergency communications
Emergency two-way communication systems shall comply with Section 11B-409.4.7.
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface.
-
11B-407.4.7.1.5 Button spacing
A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons.
-
4.3.2(2)
(2) At least one accessible route shall connect accessible buildings, facilities, elements, and spaces that are on the same site....
-
11B-411.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-411.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
11B-411.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-411.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
11B-411.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-411.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
4.1.1(2)
(2) At least one accessible route complying with 4.3 shall connect accessible buildings, facilities, elements, and spaces that are on the same site....
-
11B-407.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-407.3.
-
11B-407.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-407.3.
-
11B-407.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-407.3.