This provision helps ensure that elevator doors remain open long enough for persons with disabilities to travel from call buttons to the responding car and is based on a travel speed of...
Search Results "Elevator Building"
-
Door and Signal Timing
-
4.10.3 Hall Call Buttons
Call buttons in elevator lobbies and halls shall be centered at 42 in (1065 mm) above the floor....
-
4.10.3 HALL CALL BUTTONS
Call buttons in elevator lobbies and halls shall be centered at 42 in (1065 mm) above the floor....
-
1007.4 Elevators
The elevator shall be accessed from either an area of refuge complying with Section 1007.6 or a horizontal exit....
-
General
Section 207.1 of the 2010 Standards reference the International Building Code (IBC) for scoping and technical requirements for accessible means of egress....
-
11B-408.4.1 Car dimensions and doors
Elevator cars shall provide a clear width 42 inches (1067 mm) minimum and a clear depth 54 inches (1372 mm) minimum....
-
11B-408.4.1 Car dimensions and doors
Elevator cars shall provide a clear width 42 inches (1067 mm) minimum and a clear depth 54 inches (1372 mm) minimum....
-
11B-407.4.8.1.3 Floor arrival
As the car passes a floor and when a car stops at a floor served by the elevator, the corresponding character shall illuminate. Exception: Reserved....
-
4.3.2(2)
(2) At least one accessible route shall connect accessible buildings, facilities, elements, and spaces that are on the same site....
-
4.1.1(2)
(2) At least one accessible route complying with 4.3 shall connect accessible buildings, facilities, elements, and spaces that are on the same site....
-
407.4.6.2 Buttons
EXCEPTION: In existing elevators, buttons shall be permitted to be recessed....
-
407.4.6.2 Buttons
EXCEPTION: In existing elevators, buttons shall be permitted to be recessed....
-
11B-407.4.10 Support rail
Support rails in elevator cabs are used in a different way than handrails along a walking surface such as a ramp or stairway....
-
4.1.2(2)
(2) At least one accessible route complying with 4.3 shall connect accessible buildings, accessible facilities, accessible elements, and accessible spaces that are on the same site....
-
407.4.6.2 Buttons
EXCEPTION: In existing elevators, buttons shall be permitted to be recessed....
-
Height: ADA Standard Section 1008.3.2.2
Each transfer step shall be 8 inches (205 mm) high maximum.
-
Size: ADA Standard Section 1008.3.1.1
Transfer platforms shall have level surfaces 14 inches (355 mm) deep minimum and 24 inches (610 mm) wide minimum.
-
Height: ADA Standard Section 1008.3.1.2
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface.
-
Size: ADA Standard Section 1008.3.2.1
Transfer steps shall have level surfaces 14 inches (355 mm) deep minimum and 24 inches (610 mm) wide minimum.
-
11B-411.4.6.2 Buttons
Car control buttons shall comply with Sections 11B-407.4.6.2.1 and 11B-407.4.6.2.4. The car shall not have non-functional, exposed floor buttons.
-
11B-411.4.10 Support rail
Support rails complying with Section 11B-407.4.10 shall be provided on at least one wall of the car.
-
11B-411.4.9 Emergency communication
Emergency communication shall comply with Section 11B-407.4.9.
-
11B-407.4.7.1.5 Button spacing
A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons.
-
11B-407.4.7.1.1 Type
Control buttons shall be identified by raised characters or symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section...