207.1 General
-
11B-809.10.4 Sufficient maneuvering space
Where doors swing into the toilet and bathing or powder rooms required to comply with Section 11B-809.10, a clear maneuvering space of 30 (762 mm) inches by 48 inches (1219 mm) minimum shall...
-
Alterations [§206.4 and §202.4]
Alterations [§206.4 and §202.4] In alterations to existing facilities, accessible entrances are required: if an existing entrance is altered (and no fully compliant...
- Bradley 1-Stall Seat Cover/Tissue Dispenser 5922
- Bradley 2-Stall Seat Cover/Tissue Dispenser 5921
-
Railings—Guardrails, Handrails, and Safety
For safety, the International Building Code (IBC), http://www.iccsafe.org, section 1003.2.12 contains requirements for guardrail height and the spacing of rails where there is a drop off...
-
Is turning space required in all rooms and spaces?
Turning space is required in certain spaces, such as toilet and bathing facilities, dressing and fitting rooms, and transient lodging guest rooms....
-
11B-703.1.1 Plan review and inspection
Signs as specified in Section 11B-703, or in other sections of this code, when included in the construction of new buildings or facilities, or when included, altered or replaced due to additions...
-
604.8.1.1 Size
The minimum space required in toilet compartments is provided so that a person using a wheelchair can maneuver into position at the water closet....
-
604.8.1.1 Size
The minimum space required in toilet compartments is provided so that a person using a wheelchair can maneuver into position at the water closet....
-
604.8.1.1 Size
The minimum space required in toilet compartments is provided so that a person using a wheelchair can maneuver into position at the water closet....
-
Restrooms Main Lobby
The handles, locks, and other operating devices of the men's and women's toilet stall doors do not have a shape that is easy to grasp with one hand and require tight grasping and twisting...
-
CASI Accessibility Construction Inspection Checklist
It is important during the progress inspections that the building inspector verify all elements will be able to meet the minimum accessibility requirements of the California Building Code...
-
CALBO Accessibility Construction Inspection Checklist
It is important during the progress inspections that the building inspector verify all elements will be able to meet the minimum accessibility requirements of the California Building Code...
-
603.2.1 Turning Space
Turning space complying with 304 shall be provided within the room. [ECTCR UFAS 4.22.3 Exception]
-
11B-603.2.1 Turning space
Turning space complying with Section 11B-304 shall be provided within the room.
-
603.2.1 Turning Space
Turning space complying with 304 shall be provided within the room.
-
H3
H3. Is the hardware (e.g., lever, pull, panic bar) usable with one hand without tight grasping, pinching, or twisting of the wrist? [ADA Standards § 4.13.9] Yes No If...
-
603.2.1 Turning Space
603.2.1 Turning Space. Turning space complying with 304 shall be provided within the room.
-
5.3.3.2 Location Where Walls Provided
Where walls or partitions are provided, the seat shall be positioned with a wall or partition to the rear and to one side of the seat for a left-hand or right-hand approach. The back...
-
603.2.1 Turning Space
Turning space complying with 304 shall be provided within the room.
-
11B-603.2.1 Turning space
11B-603.2.1 Turning space. Turning space complying with Section 11B-304 shall be provided within the room.
-
11B-604.8.1.4 Toe clearance
11B-604.8.1.4 Toe clearance. At least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond...