[See subsections ...]
Search Results "Outdoor Rinsing Shower"
-
610 Seats
-
610 Seats
[See subsections ...]
-
610 Seats
610 Seats
-
11B-809.10.6.5 Thresholds
Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the...
-
11B-206.5.3 Transient lodging facilities
Exception: Shower and sauna doors in guest rooms that are not required to provide mobility features complying with Section 11B-806.2 shall not be required to comply with Section 11B-404.2.3...
- Bobrick Two-Wall Tub/Shower Toilet Compartment Grab Bar B-68137
- Bobrick Two-Wall Tub/Shower Toilet Compartment Grab Bar B-5837
-
11B-206.5.3 Transient lodging facilities
Exception: Shower and sauna doors in guest rooms that are not required to provide mobility features complying with Section 11B-806.2 shall not be required to comply with Section 11B-404.2.3...
- Bobrick Two-Wall Tub/Shower Toilet Compartment Grab Bar Peened B-5837.99
- Bobrick Two-Wall Tub/Shower Toilet Compartment Grab Bar Peened B-68137.99
- Landscape Forms Inc. Select Modular Steel Recycling Units
-
Surface
Surface—The top layer of ground on a recreation site, outdoor recreation access route, trail, or beach access route Firm. A surface that resists deformation by indentations....
- ACO Premium Linear QuARTz Drain
-
When is a facility considered accessible?
For developed recreation areas: The Forest Service Outdoor Recreation Accessibility Guidelines (FSORAG) apply to Forest Service outdoor recreation areas....
-
1011.6 Water Spouts
Water spouts at water hydrants and water utility hook-ups shall be 28 inches (710 mm) minimum and 36 inches (915 mm) maximum above the ground.
-
Surface [1016.2]
The surfaces of ORARs, passing spaces, and resting intervals must be firm and stable. Additional information on firm and stable surfaces is provided in the trails section of this...
-
2.10.1 Clear Width
Gate openings and openings in barriers for pedestrian passage shall provide a clear width of 36 inches (915 mm), complying with ODAAG, section 1017.3 Clear Tread Width.
-
4.5.2.1 Forward Approach
The clear floor or ground space for a forward approach shall be 36 inches (915 mm) by 48 inches (1220 mm).
-
4.5.2.2 Side Approach
The clear floor or ground space for a side approach shall be 30 inches (760 mm) by 60 inches (1525 mm).
-
1011.6 Water Spouts
Water spouts at water hydrants and water utility hook-ups shall be 28 inches (710 mm) minimum and 36 inches (915 mm) maximum above the ground.
-
Position of Grab Bars: ADA Standard Section 609.4
Section 609.4 covers the current ADA Standards for the position of grab bars.
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface,...
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface,...
- Kessel Design Linearis Super60 Trench Drain