Knee and toe space complying with Section 11B-306 shall be provided at sinks and work surfaces required to comply with Section 11B-809.9.4. Exception: Removable base cabinets...
Search Results "Dwelling (FHA)"
Commonly Searched Documents
-
11B-809.9.3 Removable base cabinets
-
TEST NO. 2 – SITE ANALYSIS TEST
Determine the requirement of providing an accessible route to planned multifamily dwellings based on the topography of the existing natural terrain....
-
TEST NO. 2 – SITE ANALYSIS TEST
Determine the requirement of providing an accessible route to planned multifamily dwellings based on the topography of the existing natural terrain....
-
1134A.7, Item 4
4. Water closet controls. Water closet controls shall be mounted no more than 44 inches (1118 mm) above the floor. The force required to activate controls shall be no greater...
-
1133A.7.1 Plumbing protection
1133A.7.1 Plumbing protection. Water supply and drain pipes under kitchen sinks shall be insulated or otherwise covered to protect against contact. There shall be no sharp or...
-
1133A.4, Item 3
3. Sinks and work surfaces may be a single integral unit a minimum of 60 inches (1524 mm) in length, or be separate components. Exception: Two 15-inch (381 mm) wide minimum...
-
1134A.8, Item 1
1. Location. Vanities and lavatories shall be installed with the centerline of the fixture a minimum of 18 inches (457 mm) horizontally from an adjoining wall or fixture to...
-
1132A.3, Item 1
1. Doors shall not be less than 6 feet 8 inches (2032 mm) in height.
-
1133A.2.1, Item 1
1. U-shaped kitchens, designed with parallel approach at a range or cooktop located at the base of the U, shall have a minimum clear width of at least 60 inches (1524 mm). (See...
-
1134A.6, Item 3
3. Floor space. A clear maneuvering space at least 30 inches in width by 48 inches in length (762 mm by 1219 mm) shall be located outside the shower, flush and parallel to the...
-
1134A.5, Item 3
3. Bathtub controls. Faucet controls and operation mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist. The...
-
1134A.8, Item 7
7. Lavatory faucet controls. Faucet controls and operation mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the...
-
1134A.8, Item 3
3. Cabinets. Cabinets under lavatories are acceptable provided the bathroom has space to allow a parallel approach by a person in a wheelchair and the lavatory cabinets are...
-
1134A.6, Item 1.2
1.2 The shower stall shall measure at least 30 inches deep by 60 inches wide (762 mm by 1524 mm) with an entrance opening of at least 60 inches (1524 mm). A water closet may...
-
4.34.5.3 LAVATORY, MIRRORS, AND MEDICINE CABINETS
(1) The lavatory and mirrors shall comply with 4.22.6. (2) If a cabinet is provided under the lavatory in adaptable bathrooms, then it shall be removable to provide the clearances...
-
1132A.3, Item 1
1. Doors shall not be less than 6 feet 8 inches (2032 mm) in height.
-
1134A.5, Item 3
3. Bathtub controls. Faucet controls and operation mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist. The force...
-
1133A.2.1, Item 1
1. U-shaped kitchens, designed with parallel approach at a range or cooktop located at the base of the U, shall have a minimum clear width of at least 60 inches (1524 mm). (See...
-
1134A.8, Item 1
1. Location. Vanities and lavatories shall be installed with the centerline of the fixture a minimum of 18 inches (457 mm) horizontally from an adjoining wall or fixture to allow for...
-
1134A.6, Item 1.2
1.2. The shower stall shall measure at least 30 inches deep by 60 inches wide (762 mm by 1524 mm) with an entrance opening of at least 60 inches (1524 mm). A water closet may project...
-
1134A.6, Item 3
3. Floor space. A clear maneuvering space at least 30 inches in width by 48 inches in length (762 mm by 1219 mm) shall be located outside the shower, flush and parallel to the...
-
1134A.8, Item 3
3. Cabinets. Cabinets under lavatories are acceptable provided the bathroom has space to allow a parallel approach by a person in a wheelchair and the lavatory cabinets are designed...
-
1134A.7, Item 4
4. Water closet controls. Water closet controls shall be mounted no more than 44 inches (1118 mm) above the floor. The force required to activate controls shall be no greater than 5...
-
1133A.4, Item 3
3. Sinks and work surfaces may be a single integral unit a minimum of 60 inches (1524 mm) in length, or be separate components. Exception: Two 15-inch (381 mm) wide minimum...