4. Water closet controls. Water closet controls shall be mounted no more than 44 inches (1118 mm) above the floor. The force required to activate controls shall be no greater than 5...
Search Results "Dwelling (FHA)"
Commonly Searched Documents
-
1134A.7, Item 4
-
1133A.4, Item 3
3. Sinks and work surfaces may be a single integral unit a minimum of 60 inches (1524 mm) in length, or be separate components. Exception: Two 15-inch (381 mm) wide minimum...
-
1133A.7.1 Plumbing protection
Water supply and drain pipes under kitchen sinks shall be insulated or otherwise covered to protect against contact. There shall be no sharp or abrasive surfaces under kitchen sinks.
-
11B-809.10.5.4 Bathtub enclosures
Doors and panels of bathtub enclosures shall be constructed from approved, shatter-resistant materials. Hinged doors shall open outward. Glazing used in doors and panels of bathtub...
-
11B-809.10.6.5 Thresholds
Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the...
-
11B-809.9.4 Work surfaces
Work surfaces shall be 36 inches (914 mm) maximum above the finish floor with minimum lengths at the following locations as required by this section: Linear length of 30...
-
1133A.7.1 Plumbing protection
Water supply and drain pipes under kitchen sinks shall be insulated or otherwise covered to protect against contact. There shall be no sharp or abrasive surfaces under kitchen sinks.
-
11B-607.4 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in bathtubs located in bathing facilities provided that reinforcement has been installed in walls and located...
-
11B-233.1 General
Public housing facilities with residential dwelling units available for public use shall comply with Section 11B-233....
-
11B-607.4 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in bathtubs located in bathing facilities provided that reinforcement has been installed in walls and located...
-
11B-607.4 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in bathtubs located in bathing facilities provided that reinforcement has been installed in walls and located...
-
1132A.1 Primary entry doors and required exit doors
., entry or exit doors which open from the covered multifamily dwelling unit into a corridor, hallway or lobby, or directly to the outside)....
-
1132A.1 Primary entry doors and required exit doors
., entry or exit doors which open from the covered multifamily dwelling unit into a corridor, hallway or lobby, or directly to the outside)....
-
11B-604.3.2 Overlap
Exception: In residential dwelling units, a lavatory complying with Section 11B-606 shall be permitted on the rear wall 18 inches (457 mm) minimum from the water closet centerline where...
-
11B-604.3.2 Overlap
Exception: In residential dwelling units, a lavatory complying with Section 11B-606 shall be permitted on the rear wall 26 inches (660 mm) minimum from the water closet centerline to allow...
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
-
11B-233.1 General
Public housing facilities with residential dwelling units available for public use shall comply with Section 11B-233....
-
1132A.1 Primary entry doors and required exit doors
., entry or exit doors which open from the covered multifamily dwelling unit into a corridor, hallway or lobby, or directly to the outside)....
-
11B-608.3 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in showers located in bathing facilities provided that reinforcement has been installed in walls and located...
-
11B-608.3 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in showers located in bathing facilities provided that reinforcement has been installed in walls and located...
-
11B-608.3 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in showers located in bathing facilities provided that reinforcement has been installed in walls and located...
-
11B-233.1 General
This section addresses long-term living (non-transient), public housing dwelling units....
-
11B-224.7 Housing at a place of education
Exception: Housing facilities that are provided by or on behalf of a place of education, with residential dwelling units leased on a year round basis exclusively to graduate students or...
-
Section 35.151(e) Social service center establishments
First, for the first time, residential dwelling units are explicitly covered in the 2004 ADAAG in section 233....