Maneuvering Clearances at Doors [4.13.6] Pull-side clearance beyond the door swing provides space for a forward reach to door hardware....
Search Results "Toilet Room Door"
-
Maneuvering Clearances at Doors [4.13.6]
-
11B-404.2.4.3 Recessed doors and gates
, measured perpendicular to the face of the door or gate...
-
11B-404.2.4.3 Recessed doors and gates
, measured perpendicular to the face of the door or gate...
-
R218 Doors, Doorways, and Gates (Section-by-Section Analysis)
R218 Doors, Doorways, and Gates (Section-by-Section Analysis) Doors, doorways, and gates to pedestrian facilities such as transit shelters must comply with applicable technical requirements...
-
Plan 1A: 13-Foot Wide Accessible Guest Room
Plan 1A: 13-Foot Wide Accessible Guest Room This drawing shows an accessible 13-foot wide guest room with features that comply with the 2010 Standards....
-
Plan 1B: 13-Foot Wide Accessible Guest Room
Plan 1B: 13-Foot Wide Accessible Guest Room This drawing shows an accessible 13-foot wide guest room with features that comply with the 2010 Standards....
-
Turning Space: ADA Standard Section 803.2
Turning space complying with 304 shall be provided within the room....
-
11B-411.3.4 Door delay
Door delay shall comply with Section 11B-407.3.5....
-
11B-411.3.4 Door delay
Door delay shall comply with Section 11B-407.3.5....
-
11B-411.3.4 Door delay
Door delay shall comply with Section 11B-407.3.5....
-
11B-216.1 General
The substantive difference between the CBC and 2010 ADA Standards scoping for signage at parking facilities is that signs identifying permanent rooms and spaces, directional and informational...
-
11B-216.1 General
The substantive difference between the CBC and 2010 ADA Standards scoping for signage at parking facilities is that signs identifying permanent rooms and spaces, directional and informational...
-
4.13.6 MANEUVERING CLEARANCES AT DOORS
Minimum maneuvering clearances at doors that are not automatic or power-assisted shall be as shown in Fig. 25....
-
Must elevator doors remain open for 20 seconds?
LULA swing doors, private residence elevator doors, and platform lift gates and doors must remain open for 20 seconds minimum....
-
Power-Operated Doors or Gates
Platform lifts are required to have power-operated doors or gates....
-
407.3.4 Door and Signal Timing
407.3.4 Door and Signal Timing....
-
11B-803.2 Turning space
Turning space complying with Section 11B-304 shall be provided within the room....
-
11B-803.2 Turning space
Turning space complying with Section 11B-304 shall be provided within the room....
-
11B-233.3.1.2.5 Public housing facility site impracticality
Doors complying with Section 11B-404. 3. Communication features complying with Section 11B-809.5.5. 4. ...
-
Door Pressure Gauge
Door Pressure Gauge This Door Pressure Gauge, available from Evan Terry Associates, measures forces from 0-35 pounds on one side and 0-16 kilograms on the other....
-
4.13.6 Maneuvering Clearances at Doors
Minimum maneuvering clearances at doors that are not automatic or power-assisted shall be as shown in Fig. 25....
-
222 Dressing, Fitting, and Locker Rooms
Where coat hooks or shelves are provided in dressing, fitting or locker rooms without individual compartments, at least one of each type shall comply with 803.5....
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...