These commenters believed that the requirement will increase the usability of accessible single-user toilet rooms by making side transfers possible for many individuals who use wheelchairs...
Search Results "Toilet Room Door"
-
Water Closet Clearance
-
404.2.6 Doors in Series and Gates in Series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1220 mm) minimum plus the width of doors or gates swinging into the space....
-
Door and Signal Timing for Hall Calls [4.10.7], Door Delay for Car Calls [4.10.8]
Timing, based on the distance between the farthest call button and the elevator door, begins with visible and audible signaling of car arrival....
- Takeform Fusion Signage Miscellaneous Room Identification Type E.2
-
11B-806.3 Guest rooms with communication features
Guest rooms required to provide communication features shall comply with Section 11B-806.3. Advisory 11B-806.3 Guest rooms with communication features....
-
11B-806.3 Guest rooms with communication features
Guest rooms required to provide communication features shall comply with Section 11B-806.3. Advisory 11B-806.3 Guest rooms with communication features....
-
1132A.3 Width and height of interior doors and secondary exterior doors
Doors shall comply with the following: Doors shall not be less than 6 feet 8 inches (2032 mm) in height. ...
-
1132A.3 Width and height of interior doors and secondary exterior doors
1132A.3 Width and height of interior doors and secondary exterior doors. Doors shall comply with the following:...
-
Can doors swing into required clear floor or ground space?
) fixture clearances in toilet and bathing facilities (except those that are single user where wheelchair space beyond the door swing is provided) (603.2.3) clear floor space...
-
404.2.4.3 Recessed Doors and Gates
404.2.4.3 Recessed Doors and Gates....
-
11B-410.6 Doors and gates
Platform lifts shall have low-energy power-operated doors or gates complying with Section 11B-404.3. Doors shall remain open for 20 seconds minimum....
-
11B-404.2.6 Doors in series and gates in series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1219 mm) minimum plus the width of doors or gates swinging into the space....
-
11B-410.6 Doors and gates
Platform lifts shall have low-energy power-operated doors or gates complying with Section 11B-404.3. Doors shall remain open for 20 seconds minimum....
-
11B-410.6 Doors and gates
Platform lifts shall have low-energy power-operated doors or gates complying with Section 11B-404.3. Doors shall remain open for 20 seconds minimum....
-
Maneuvering Clearance or Standby Power for Automatic Doors
door in emergencies....
-
F213.3.1 Toilet Compartments
Where toilet compartments are provided, at least one toilet compartment shall comply with 604.8.1....
-
213.3.1 Toilet Compartments
Where toilet compartments are provided, at least one toilet compartment shall comply with 604.8.1....
-
404.2.4.3 Recessed Doors and Gates
, measured perpendicular to the face of the door or gate....
-
213.3.1 Toilet Compartments
213.3.1 Toilet Compartments. Where toilet compartments are provided, at least one toilet compartment shall comply with 604.8.1....
-
404.2.4.3 Recessed Doors and Gates
, measured perpendicular to the face of the door or gate....
-
11B-206.5 Doors, doorways, and gates
Doors, doorways, and gates providing user passage shall be provided in accordance with Section 11B-206.5. ...
-
11B-206.5 Doors, doorways, and gates
Doors, doorways, and gates providing user passage shall be provided in accordance with Section 11B-206.5....
-
11B-206.5 Doors, doorways, and gates
Doors, doorways, and gates providing user passage shall be provided in accordance with Section 11B-206.5....
-
404.2 Manual Doors, Doorways, and Manual Gates
404.2 Manual Doors, Doorways, and Manual Gates. Manual doors and doorways and manual gates intended for user passage shall comply with 404.2....