If yes, is a ramp or sloped hallway provided? Yes _____ No _____ If yes, go to question E1-4. Note: A ramp, lift, or elevator can be used to provide access to floor levels....
Search Results "Ramp Slope"
Commonly Searched Documents
-
3a.
-
11B-1009.3.2 Submerged depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (762 mm) maximum below the stationary water level....
-
11B-1009.3.2 Submerged depth
Sloped entries shall extend to a depth of 24 inches (610 mm) minimum and 30 inches (762 mm) maximum below the stationary water level....
-
Exterior Routes
travel. 11B-302.3 Vertical change in level 1/4 inch high maximum. 11B-303.2 Changes in level greater than 1/2 inch ramped...
-
Exterior Routes
travel. 11B-302.3 Vertical change in level 1/4 inch high maximum. 11B-303.2 Changes in level greater than 1/2 inch ramped...
-
3.4.5 Grade
The clear ground space and turning space required by section 3.4.3 shall have a slope of no more than 1:48 (2 percent) in any direction. Exception....
-
4.7.6 Built-up Curb Ramps
Built-up curb ramps shall be located so that they do not project into vehicular traffic lanes (see Fig. 13)....
-
4.7.6 BUILT-UP CURB RAMPS
Built-up curb ramps shall be located so that they do not project into vehicular traffic lanes (see Fig. 13)....
-
1003.2.2 Boarding Piers at Boat Launch Ramps
1003.2.2 Boarding Piers at Boat Launch Ramps. Accessible routes serving boarding piers at boat launch ramps shall be permitted to use the exceptions in 1003.2.2. EXCEPTIONS: 1....
-
F242.3 Wading Pools
Accessible means of entry shall comply with sloped entries complying with 1009.3....
-
242.3 Wading Pools
Accessible means of entry shall comply with sloped entries complying with 1009.3....
-
11B-242.3 Wading pools
Accessible means of entry shall comply with sloped entries complying with Section 11B-1009.3. ...
-
11B-242.3 Wading pools
Accessible means of entry shall comply with sloped entries complying with Section 11B-1009.3....
-
11B-242.3 Wading pools
Accessible means of entry shall comply with sloped entries complying with Section 11B-1009.3....
-
1008.2.5.2 Elevated
The rise for any ramp run connecting elevated play components shall be 12 inches (305 mm) maximum....
-
1008.2.5.2 Elevated
The rise for any ramp run connecting elevated play components shall be 12 inches (305 mm) maximum....
-
242.3 Wading Pools
Accessible means of entry shall comply with sloped entries complying with 1009.3....
-
c-i
If Yes, is a ramp or sloped hallway provided? Yes No If Yes, go to question E1-d....
-
Built-Up Curb Ramps
Built-up curb ramps are permitted, but they cannot project in parking spaces, access aisles, or vehicle traffic lanes....
-
Resting Intervals [1016.8]
Resting intervals are required at the top and bottom of an ORAR section any time the running slope exceeds 1:20 (5 percent)....
-
Accessible Means of Entry to Wading Pools
Sections 242.3 and 1009.3 of the 2010 Standards require that at least one sloped means of entry is required into the deepest part of each wading pool....
-
1008.2.5.2 Elevated
The rise for any ramp run connecting elevated play components shall be 12 inches (305 mm) maximum....
-
1003.2.2 Boarding Piers at Boat Launch Ramps
Accessible routes serving boarding piers at boat launch ramps shall be permitted to use the exceptions in 1003.2.2. EXCEPTIONS: 1....
-
1003.2.2 Boarding Piers at Boat Launch Ramps
Accessible routes serving boarding piers at boat launch ramps shall be permitted to use the exceptions in 1003.2.2. EXCEPTIONS: 1....