[See subsections ...]
Search Results "Ramp Slope"
-
T402 Ramps and Bridgeplates
-
R309.4 Curb Ramps or Blended Transitions
R309.4 Curb Ramps or Blended Transitions. Curb ramps or blended transitions complying with R304 shall connect the access aisle to the pedestrian access route....
-
§ 38.159(c) Vehicle ramp
(c) Vehicle ramp—...
-
1018.7.1 Maximum Running Slope and Segment Length
This section requires that the running slope of any segment of a beach access route not be steeper than 1:10 (10%)....
-
11B-505.3 Continuity
Handrails shall be continuous within the full length of each stair flight or ramp run....
-
11B-505.3 Continuity
Handrails shall be continuous within the full length of each stair flight or ramp run....
-
11B-505.3 Continuity
Handrails shall be continuous within the full length of each stair flight or ramp run....
-
1016.7.1 Maximum Running Slope and Segment Length
This section requires the running slope of any segment of an outdoor recreation access route to not be steeper than 1:10 (10%)....
-
505.10.1 Top and Bottom Extension at Ramps
505.10.1 Top and Bottom Extension at Ramps. Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs....
- SafePath Courtedge™ Reducer Ramps
-
11B-402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...
-
402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...
-
11B-402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...
-
402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...
-
405.9.1 Extended Floor or Ground Surface
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505....
-
505.3 Continuity
Handrails shall be continuous within the full length of each stair flight or ramp run....
-
505.3 Continuity
Handrails shall be continuous within the full length of each stair flight or ramp run....
-
505.3 Continuity
Handrails shall be continuous within the full length of each stair flight or ramp run....
-
Handrails
Handrails Handrails are required on both sides of ramps connecting elevated play components....
-
505.3 Continuity
Handrails shall be continuous within the full length of each stair flight or ramp run....
-
Where must curb ramps be provided?
Generally, curb ramps are needed wherever a sidewalk or other pedestrian walkway crosses a curb....
-
11B-705.1.2.2.2 Parallel curb ramps
Detectable warnings at parallel curb ramps shall be located so the edge nearest the curb is 6 inches (152 mm) minimum and 8 inches (203 mm) maximum from the demarcation line at the face...
-
505.10.1 Top and Bottom Extension at Ramps
Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of ramp runs....
-
11B-402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...