(b) Clearance between counters and all opposing base cabinets, countertops, appliances or walls is at least 40 inches....
Search Results "Clearance Around Base"
-
7(1)(b)
-
7(2)(a)(i)
(i) Sufficient maneuvering space is provided within the bathroom for a person using a wheelchair or other mobility aid to enter and close the door, use the fixtures, reopen the door...
- Microsoft Word Accessibility Basics: Webinar Series Archive
-
11B-404.2.4.4 Floor or ground surface
Floor or ground surface within required maneuvering clearances shall comply with Section 11B-302....
-
11B-233.3.1.2.6 Public housing facility site impracticality
The number of adaptable residential dwelling units required in non-elevator building public housing facilities shall be determined in accordance with Chapter 11A, Section 1150A.1....
-
11B-233.3.1.2.6 Public housing facility site impracticality
ETA Editor's Note This section of the 2019 California Building Code was amended by the Division of the State Architect. The requirements in this section were previously found in...
-
4.3.5.3 180-degree turn around an obstacle
When the entry and egress aisles are less than this width, the 360-degree turn clearances should be provided at the turning area....
-
809.2.5 Bedrooms in Emergency Transportable Housing Units
Where bedrooms are less than 70 square feet, the section specifies that the furniture supplied with the unit cannot overlap the accessible route, maneuvering clearances required at doors...
- SafePath: Overview of Ramps and Reducers for ADA Compliance by SafePath Products
-
Grab Bars
Grab bars with noncircular cross sections must not be more than 2 inches (51 millimeters) across and must be 4 to 4.8 inches (100 to 120 millimeters) around....
-
§ 38.23(b)(13) Handrails
Handrails shall be placed to provide a minimum 11⁄2 inches knuckle clearance from the nearest adjacent surface....
-
§ 38.125(b)(13) Handrails
Handrails shall be placed to provide a minimum 11/2 inches knuckle clearance from the nearest adjacent surface....
-
1132A.5.1 General
Section 1126A.3 shall apply to maneuvering clearances at the side of the door exposed to common or public use spaces. ...
-
§ 38.115(a)
Handrails shall be placed to provide a minimum 11/2 inches knuckle clearance from the nearest adjacent surface....
-
§ 38.159(b)(13) Handrails
Handrails shall be placed to provide a minimum 11/2 inches (38 mm) knuckle clearance from the nearest adjacent surface....
-
§ 38.29(b)
Handrails shall be placed to provide a minimum 11/2 inches knuckle clearance from the nearest adjacent surface....
-
Accessible Passenger Loading Zones [§503]
Passenger Loading Zones [§503] Requirements for accessible passenger loading zones address vehicle pull-up spaces and access aisles, including their dimensions, surfacing, and vertical clearance...
-
Three Additional Features for Van-Accessible Parking Spaces
seen when a vehicle is parked in the space 96" min. width access aisle, level (max. slope 1:50 in all directions), located beside the van parking space Min. 98-inch-high clearance...
-
11B-224.8.1 More than 25-bed sleeping rooms
In sleeping rooms with more than 25 beds, a minimum of 5 percent of the beds shall have clear floor space complying with Section 11B-806.2.3.
-
Question 19
YES/NO 19. Are the entrances to accessible public restrooms and fitting rooms free of obstacles that block the clear wall and floor space needed for...
-
K3
K3. In each eating area, if tables with fixed seats are provided, do at least 5% of each type of table with fixed seats have accessible locations with knee space at least 27 inches...
-
4.24.5 Clear Floor Space
A clear floor space at least 30 in by 48 in (760 mm by 1220 mm) complying with 4.2.4 shall be provided in front of a sink to allow forward approach. The clear floor space shall be on...
-
4.24.5 CLEAR FLOOR SPACE
A clear floor space at least 30 in by 48 in (760 mm by 1220 mm) complying with 4.2.4 shall be provided in front of a sink to allow forward approach. The clear floor space shall be on...
-
11B-224.8.1 More than 25-bed sleeping rooms
In sleeping rooms with more than 25 beds, a minimum of 5 percent of the beds shall have clear floor space complying with Section 11B-806.2.3.