(a) The minimum clear floor area should be 35 inches (890 mm) by 60 inches (1525 mm). Permanently installed fixtures may overlap this area a maximum of 6 inches (150 mm), if the...
Search Results "Clearance Around Base"
-
(1)(a)
-
§ 38.123(a)(1)
(1) The minimum clear floor area shall be 35 inches by 60 inches. Permanently installed fixtures may overlap this area a maximum of 6 inches, if the lowest portion of the fixture is...
-
11B-306.2.3 Minimum required depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (432 mm) minimum under the element. Exceptions: 1. ...
-
11B-306.2.3 Minimum required depth
Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (432 mm) minimum under the element....
-
604.9.6 Dispensers
There shall be a clearance of 1 1/2 inches (38 mm) minimum below the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow....
-
604.9.6 Dispensers
There shall be a clearance of 1½ inches (38 mm) minimum below the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow....
-
11B-604.9.6 Dispensers
There shall be a clearance of 1½ inches (38 mm) minimum below the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow....
-
11B-604.9.6 Dispensers
There shall be a clearance of 1½ inches (38 mm) minimum below the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow....
- Bobrick Accessibility Video -- Mounting Height and Reach Ranges
- Figure 1005.3.2 Extended Ground or Deck Surface at Fishing Piers and Platforms – Drawing from the U.S. Access Board
-
11B-604.9.6 Dispensers
There shall be a clearance of 11/2 inches (38 mm) minimum below the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow....
-
Are state and local government websites required to be accessible?
The Department of Justice considers websites to be an integral aspect of how Title II entities interact with their citizens and the public and therefore they need to be accessible....
-
Web Accessibility
The increasing use of web sites allows for easy and convenient access to the programs, services, and activities of public entities. The public can pay fines, apply for benefits,...
-
T303 Handrails, Stanchions, and Handholds
The technical requirements for handrails, stanchions, and handholds include specifications on edges, cross sections, and clearances (i.e., space between gripping surface and adjacent surface...
-
1016.9 Protruding Objects
However, entities should maintain the vertical clearance along outdoor recreation access routes, resting intervals, and passing spaces free from tree branches for 80 inches high minimum...
-
404.2.4.4 Floor or Ground Surface
Floor or ground surface within required maneuvering clearances shall comply with 302. Changes in level are not permitted. EXCEPTIONS: 1....
-
404.2.4.4 Floor or Ground Surface
Floor or ground surface within required maneuvering clearances shall comply with 302. Changes in level are not permitted. EXCEPTIONS: 1....
-
1133A.2, Item 2
2. A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or forward approach shall be provided at the kitchen sink and all other...
-
1133A.2 Clear floor space
1133A.2 Clear floor space. Clear floor space at kitchens shall comply with the following:
-
Question 10
YES/NO 10. Is the accessible entrance into the building free of obstacles that block the clear wall and floor space needed for opening the door...
-
1k
k. Is the gap between the wall and the inside face of each grab bar exactly 1 1/2" to accommodate persons with disabilities who rest their forearms on the bars for stabilization so...
-
C. Doors
C. Doors - Examine each of the interior routes described above: ...with the exception of doors at shallow closets, do the doors to required accessible spaces, and all doors into...
-
J6
J6. Is the bottom of the apron of the fountain 27 inches above the floor so that it provides the space needed for a person who uses a wheelchair to pull up under it but is not a...
-
9.2.2(1)
(1) Accessible sleeping rooms shall have a 36 in (915 mm) clear width maneuvering space located along both sides of a bed, except that where two beds are provided, this requirement...