Where an EV charger can simultaneously charge more than one vehicle, the number of EV chargers provided shall be considered equivalent to the number of electric vehicles that can be simultaneously...
Search Results "Vehicle Ramp"
-
11B-228.3.2 Minimum number
-
11B-1003.2.2 Boarding piers at boat launch ramps
Accessible routes serving boarding piers at boat launch ramps shall be permitted to use the exceptions in Section 11B-1003.2.2....
-
11B-406.3.2 Turning space
A turning space 48 inches (1219 mm) minimum by 48 inches (1219 mm) minimum shall be provided at the bottom of the curb ramp....
-
11B-1003.2.2 Boarding piers at boat launch ramps
Accessible routes serving boarding piers at boat launch ramps shall be permitted to use the exceptions in Section 11B-1003.2.2. Exceptions: 1. ...
-
11B-1003.2.2 Boarding piers at boat launch ramps
Accessible routes serving boarding piers at boat launch ramps shall be permitted to use the exceptions in Section 11B-1003.2.2. Exceptions: 1....
-
Re: When is a Curb Ramp a Ramp?
I leave it up to the AHJ to define curb heights in order to apply them to the definition of a curb ramp. Most of the time that provides a max height of 7". ...
-
4.7.3 Width
The minimum width of a curb ramp shall be 36 in (915 mm), exclusive of flared sides....
-
4.7.3 WIDTH
The minimum width of a curb ramp shall be 36 in (915 mm), exclusive of flared sides....
- GameTime ADA Wide Ramp Attachment 3D
-
City of Bend Oregon Curb Ramp Commitment
Requires the Registered User plan or above. Login!
-
T404.2 Vehicle Floor and Boarding Platform Coordination
The design of non-rail vehicles shall be coordinated with the boarding platforms to minimize the gap between the vehicle floor and the boarding platforms....
-
Additional Technical Criteria Considered for Handrails on Ramps
M303.3.3.5 would require handrails to be provided on each side of the ramp when the vertical rise of the ramp exceeds 6 inches....
-
Electric Vehicle Charging Stations, Accessibility: FAQs
[See subsections ...]
-
R407.6.4 Change in Direction
Ramps that change direction between runs at landings shall have a clear landing 1.5 m (5.0 ft) minimum by 1.5 m (5.0 ft) minimum....
-
11B-309 Operable parts
TITLE NOTES 11B-309 Operable parts Adds to existing exception for 5 lb. maximum operating force requirement for electric vehicle...
-
Access Aisle: ADA Standard Section 503.3
Section 503.3 covers the current ADA Standards for access aisle at passenger loading zones.
-
DSA Drawing 11B-406-3 Perpendicular Curb Ramp next to a Curb and Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
1007.2 Accessible Routes
Ramp landing slopes specified by 405.7.1 shall be permitted to be 1:20 maximum. 5....
-
1007.2 Accessible Routes
Ramp landing slopes specified by 405.7.1 shall be permitted to be 1:20 maximum. 5....
-
Q3: Roadway Resurfacing Alteration Project and Curb Ramp Improvements
Q3: If a roadway resurfacing alteration project does not span the full width of the road, do I have to put in curb ramps?...
-
Roadway resurfacing, curb ramps at crosswalks
If roadways are being resurfaced or otherwise altered as part of a BRT project, curb ramps must be installed at crosswalks that have been affected. (DOT ADA Standard 106.5.)...
-
11B-1008.2.5.1 Ground level
Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16....
-
1008.2.5.1 Ground Level
Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16....