405.7.3 Length
The landing clear length shall be 60 inches (1525 mm) long minimum.
-
11B-405.7.2.1
Top landings shall be 60 inches (1524 mm) wide minimum.
-
405.7.3 Length
The landing clear length shall be 60 inches (1525 mm) long minimum.
-
R407.6.3 Length
R407.6.3 Length. The landing clear length shall be 1.5 m (5.0 ft) long minimum.
-
405.7.3 Length
405.7.3 Length. The landing clear length shall be 60 inches (1525 mm) long minimum.
-
11B-405.7.3 Length
The landing clear length shall be 60 inches (1524 mm) long minimum.
-
4.8.4(2)
(2) The landing length shall be a minimum of 60 in (1525 mm) clear.
-
11B-405.7.2.1
Top landings shall be 60 inches (1524 mm) wide minimum.
-
11B-405.7.3 Length
The landing clear length shall be 60 inches (1524 mm) long minimum.
-
11B-405.7.3 Length
The landing clear length shall be 60 inches (1524 mm) long minimum.
-
3. Are ramps, transfer systems, and stairs permitted to be counted as play components?
Are ramps, transfer systems, and stairs permitted to be counted as play components? No....
-
DSA Drawing 11B-406-10C Curb Ramp Adjoining a Parking Access Aisle with No Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Detectable Warnings [4.7.7]
Since curb ramps remove this detectable drop-off, ADAAG originally required a distinctive dome patterning for the surface of curb ramps detectable by canes or by foot so that people with...
-
Can you put an EV charger in an existing accessible parking space instead of doing costly upgrades?
Section 11B-208.1 notes, “For the purposes of this section, electric vehicle charging stations are not parking spaces…”...
-
For small parking lots, is there any variance on being able to share EV charging with the existing accessible parking spaces?
Section 11B-208.1 notes, “For the purposes of this section, electric vehicle charging stations are not parking spaces…”...
-
1.1.15 Flatness of ramp landings
1.1.15 Flatness of ramp landings. Measure ramp landings at the midpoints of each landing in each direction using a 24 - in (600 mm) digital inclinometer....
-
1012.1 General
Parking spaces within camping units and picnic units with mobility features and pull-up spaces for recreational vehicles at dump stations shall comply with 1012....
-
1012.1 General
Parking spaces within camping units and picnic units with mobility features and pull-up spaces for recreational vehicles at dump stations shall comply with 1012....
-
f-v
If a ramp is more than 30 feet long, is a level landing at least 60 inches long provided at every 30 feet of horizontal length?...
-
T402.3 Installation and Operation
When used for boarding and alighting, ramps and bridgeplates shall be firmly attached to the non-rail vehicle to prevent displacement....
-
§ 38.125(c)(4) Ramp barriers
(4) Ramp barriers. Each side of the ramp or bridge plate shall have barriers at least 2 inches high to prevent mobility aid wheels from slipping off....
-
11B-1008.2.5.3 Handrails
Where required on ramps serving play components, the handrails shall comply with Section 11B-505 except as modified by Section 11B-1008.2.5.3....
-
11B-1008.2.5.3 Handrails
Where required on ramps serving play components, the handrails shall comply with Section 11B-505 except as modified by Section 11B-1008.2.5.3. Exceptions: 1. ...