Transfer type shower compartments shall be 36 inches (914 mm) by 36 inches (914 mm) clear inside dimensions measured at the center points of opposing sides and shall have a 36 inch (914...
Search Results "Dimension Range"
-
11B-608.2.1 Transfer type shower compartments
-
4.16.3 Height
All of the institutional designs included a raised toilet within the 17"-19" range allowed by ADAAG....
-
11B-603.4 Coat hooks, shelves and medicine cabinets
Coat hooks shall be located within one of the reach ranges specified in Section 11B-308....
-
11B-803.5 Coat hooks and shelves
Coat hooks provided within the room shall be located within one of the reach ranges specified in Section 11B-308....
-
3. Buttock-Popliteal Length
The median (50th percentile) values for buttock-popliteal length across the 6 sub-groups ranged from 18.5-19.5 in....
-
§ 1194.21(j)
(j) When a product permits a user to adjust color and contrast settings, a variety of color selections capable of producing a range of contrast levels shall be provided....
-
§ 1194.25(h)
(h) When a product permits a user to adjust color and contrast settings, a range of color selections capable of producing a variety of contrast levels shall be provided....
-
11B-813.2.5 Coat hook
No fewer than one coat hook shall be provided in close proximity to the changing table and within one of the reach ranges specified in Section 11B-308....
-
Bed Height Fact Sheet
Hotels need to adopt the recommended bed height range so individuals can safely transfer to and from the bed....
-
1. Question: What is the minimum width needed for a non-level boarding railroad passenger station platform to meet the accessibility requirements of the Americans with Disabilities Act (ADA)?
conventional non-level boarding side passenger platform with a railing or wall on the platform side opposite the track, the minimum platform width thus should be the sum of the maximum dimensions...
-
EXHIBIT B
EXHIBIT B The average anthropometric dimensions employed shall be: (1) average eye height for a person sitting in a wheelchair is 47.45"; (2) horizontal distance from the eye of an average...
-
4.13.6 MANEUVERING CLEARANCES AT DOORS
Entry doors to acute care hospital bedrooms for in-patients shall be exempted from the requirement for space at the latch side of the door (see dimension "x" in Fig. 25) if the door is at...
-
Clear floor space at Lav
Terry, You should identify the minimum dimensions of the clear floor space at the Lav....
-
605.1 General
Stall-type urinals provide greater accessibility for a broader range of persons, including people of short stature....
-
605.1 General
Stall-type urinals provide greater accessibility for a broader range of persons, including people of short stature....
-
Safe Harbor – Construction Prior to March 15, 2012
For example, the 1991 Standards allow 54 inches maximum for a side reach range to a control such as the operating part of a paper towel dispenser....
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding No Weight - Forward Approach Scooter
Horizontal distances in the positive range represent offset distance away from the body (or barrier depth) when reaching over an obstruction in relation to the forward-most point, and the...
-
11B-603.4 Coat hooks, shelves and medicine cabinets
Coat hooks shall be located within one of the reach ranges specified in Section 11B-308....
-
18 Inch Low Height
individuals indicated that they would be willing to compromise, but virtually all of the subcommittee members indicated that the 17 inch low height was the most inclusive and reached a broader range...
-
M302.2.3 Size (Section-by-Section Analysis)
increased to 17 inches, a disability advocate recommended increasing the width to 23 inches, two of the commenters, accessibility consultant and disability advocate, stated that the proposed dimensions...
-
5.8.2.5 Toe Height Recommendation
A toe space dimension usually defines a static unobstructed space. However, in the case of mammography, as the breast platform moves up and down, the toe space changes....
-
11B-706.4 Sound pressure level
Assistive listening systems shall be capable of providing a sound pressure level of 110 dB minimum and 118 dB maximum with a dynamic range on the volume control of 50 dB....
-
706.4 Sound Pressure Level
Assistive listening systems shall be capable of providing a sound pressure level of 110 dB minimum and 118 dB maximum with a dynamic range on the volume control of 50 dB....
-