A LONGITUDINAL STUDY OF PLAYGROUND SURFACES TO EVALUATE ACCESSIBILITY Final Report October 2013 Staff Liaison Peggy Greenwell U.S....
Search Results "Fire-Building Surface"
Commonly Searched Documents
-
A Longitudinal Study of Playground Surfaces to Evaluate Accessibility - Final Report
-
904.3.3 Check Writing Surfaces
Where provided, check writing surfaces shall comply with 902.3....
-
904.3.3 Check Writing Surfaces
Where provided, check writing surfaces shall comply with 902.3....
-
Private Funds Provided by Tenant
Private Funds Provided by Tenant: Exception 2 (202.4) shall apply to alteration projects for private buildings and facilities (as defined by 106.5.46) which are funded in their entirety...
-
11B-215.1 General
Where fire alarm systems and carbon monoxide alarm systems provide audible alarm coverage, alarms shall comply with Section 11B-215....
-
11B-215.1 General
Where fire alarm systems and carbon monoxide alarm systems provide audible alarm coverage, alarms shall comply with Section 11B-215. ...
-
11B-505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
11B-505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
11B-505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
[F] 907.5.2.3.2 Groups R-1 and R-2.1
Visible alarms shall be activated by the in-room smoke alarm and the building fire alarm system....
-
Accessible Surfaces Located In The Use Zone
Accessible Surfaces Located In The Use Zone If located within the use zone, accessible ground surfaces must also be impact attenuating and meet ASTM F 1292-04 Standard Specification for...
-
Horizontal Exits [IBC §1021 (2003), §1005.3.5 (2000)]
A horizontal exit compartmentalizes a building allowing occupants to exit the area containing the origin of a fire into another portion of the building that is protected by fire-resistance-rated...
-
StormPave Permeable Clay Pavers Installation Video 2 (Compaction)
Requires the Registered User plan or above. Login!
-
StormPave Permeable Clay Pavers Installation Video
Requires the Registered User plan or above. Login!
- Allied Industries International, Inc. Eco-Grip® Slip Resistant Safety Flooring
-
[F] 907.5.2.3.3 Groups R-1 and R-2.1
2.1 dwelling units or sleeping units in accordance with Table 907.5.2.3.3 shall be provided with a visible alarm notification appliance, activated by both the in-room smoke alarm and the building...
-
[F] 907.5.2.3.2 Groups R-1 and R-2.1
2.1 dwelling units or sleeping units in accordance with Table 907.5.2.3.2 shall be provided with a visible alarm notification appliance, activated by both the in-room smoke alarm and the building...
-
Surface: ADA Standard Section 1009.4.4
Surfaces of transfer walls shall not be sharp and shall have rounded edges....
-
Surface: ADA Standard Section 1009.5.5
The surface of the transfer system shall not be sharp and shall have rounded edges....
- AXS Map - How to Search and Review a Place
-
Rotational Penetrometer
It can be used easily in the field, is suitable for trail use, and does not require a level surface for testing....
-
11B-306.3.4 Clearance reduction
Exception: The knee clearance shall not be reduced at built-in dining and work surfaces required to be accessible by Section 11B-226.1....
-
11B-306.3.4 Clearance reduction
Exception: The knee clearance shall not be reduced at built-in dining and work surfaces required to be accessible by Section 11B-226.1. ...
-
11B-306.3.4 Clearance reduction
Exception: The knee clearance shall not be reduced at built-in dining and work surfaces required to be accessible by Section 11B-226.1....