Residential dwelling units may be equipped with either a LULA elevator or a private residential elevator instead of a standard passenger elevator (206.6)....
Search Results "ASCII: American Standard Code for Information Interexchange"
-
LULA Elevators in Residential Dwelling Units
-
M101.4 Equivalent Facilitation (Section-by-Section Analysis)
permit the use of alternative designs or technologies that are substantially equivalent to or provide greater accessibility and usability than strict compliance with provisions in the MDE Standards...
-
Is Identification of Which Means of Egress Are Available/Closest Necessary?
Once notified, people with a speech disability can use any standard means of egress from the building....
-
HOW TO MEASURE TRANSFER HEIGHTS IS IMPORTANT
Because of these complex shapes, it is necessary to create a standard method by which to measure table seat dimensions....
-
5.2.1 Transfer Surface Size Recommendations for M301
The transfer surface size standard has two components: width and depth (see Figure 5.2.1.1) NPRM Proposed Provision: M301.2.2 Size....
-
5.2.3 Transfer Surface Measurement Recommendation for M301 and M302
5.2.3 Transfer Surface Measurement Recommendation for M301 and M302 Description: The transfer surface size standard has two components: width and depth....
-
Elevators
In newly constructed or altered facilities, elevators must comply with specific design standards regarding the following: Hall call button orientation, mounting location, and visual...
-
Doors in a Series
Section 4.13 of the ANSI Standard, which is applicable to doors in public and common use areas, provides design specifications for doors in a series....
-
Section 2. Accessible route
A route that complies with the appropriate requirements of ANSI A117.1-1986, a comparable standard, or Section 5, Requirement 1 of these guidelines is an "accessible route"....
-
410.7 Caller ID (Section-by-Section Analysis)
This requirement would be new to the 255 Guidelines, but corresponds to a similar requirement in § 1194.23(e) of the existing 508 Standards....
-
C101.1 Purpose (Section-by-Section Analysis)
exclusive authority to enforce Section 255 and issue implementing regulations; the FCC may—but is not required to—adopt the proposed guidelines when finalized as enforceable accessibility standards...
-
Shelf and Outlet
Phones should have a standard handset so that they fit the typical TTY coupler....
-
§100.201 Accessible route
reference at §100.201a), ICC/ANSI A117.1-1998 (incorporated by reference at §100.201a), CABO/ANSI A117.1-1992, ANSI A117.1-1986 (incorporated by reference at §100.201a), or a comparable standard...
-
A. Arena Assembly Seating:
See the 2010 Standards §§ 221.3, 802.3.1 and 802.3.2....
-
Carpet [§302.2]
The standards specify the maximum pile height (1/2” measured to the backing, cushion, or pad) and texture (level or textured loop, level cut pile, or level cut/uncut pile) and require firm...
-
§ 37.43(b)
section, the phrase to the maximum extent feasible applies to the occasional case where the nature of an existing facility makes it impossible to comply fully with applicable accessibility standards...
-
11B-604.7 Dispensers and disposal units
[2010 ADA Standards] 604.7 Dispensers....
-
11B-502.6.4.2
ETA Editor's Note The CBC identification requirements for accessible parking spaces and van accessible parking spaces are more extensive than those in 2010 ADA Standards....
-
11B-206.4.4.1 Location
[2010 ADA Standards] 206.4.4.1 Location....
-
11B-806.2.3 Sleeping areas
[2010 ADA Standards] 806.2.3 Sleeping Areas. At least one sleeping area shall provide a clear floor space complying with 305 on both sides of a bed....
-
11B-610.3 Shower compartment seats
A seat in a standard roll-in shower compartment shall be a folding type, shall be installed on the side wall adjacent to the controls, and shall extend from the back wall to a point within...
-
Commercial Facilities in Private Residences (Preamble, Section-by-Section Analysis)
As in the case of public accommodations located in private residences, the new construction standards only apply to the extent that a portion of the residence is designed or intended for...
-
Turnstiles and Security Gates at Entrances
Standard narrow turnstiles are not usable by wheelchair users and by most people who walk with crutches, walkers, or canes....
-
18 Inch Low Height
An example of providing a range is the pool seat lift accessibility standard per ADA and ABA 2004 Guidelines Section 1009.2.4, which clearly establishes that, even with adjustable devices...