On the pull side of the door, is there at least 18 inches clearance provided to the side of the latch if the door is not automatic or power-operated?...
Search Results "Door Operator"
Commonly Searched Documents
-
D4. Door Clearance
-
Door King Inc. DKS Easy Setup For Vehicular Slide Gate Operators
Requires the Registered User plan or above. Login!
-
404.3.1 Clear Width
The minimum clear width for automatic door systems in a doorway shall be based on the clear opening provided by all leaves in the open position....
-
404.3.1 Clear Width
The minimum clear width for automatic door systems in a doorway shall be based on the clear opening provided by all leaves in the open position. [ECTCR UFAS 4.13.5]...
-
404.3.1 Clear Width
The minimum clear width for automatic door systems in a doorway shall be based on the clear opening provided by all leaves in the open position....
-
Paragraph (d) (Advisory Guidance)
Paragraph (d) Operable without Hearing 1. Individuals who are deaf or hard of hearing cannot locate or identify controls that require hearing....
-
17. Modifications to be completed within one year
Modifications to be completed within one year: As agreed between the parties, within one year of the date of entry of this Consent Decree, Defendants shall make the following physical, operational...
-
H6
If the entry has a vestibule, is there a 30-inch by 48-inch clear floor space inside the vestibule where a wheelchair or scooter user can be outside the door swing?...
-
Paragraph (b) Operable with low vision and limited or no hearing (Section-by-Section Analysis)
Paragraph (b) Operable with low vision and limited or no hearing (Section-by-Section Analysis) Comment....
-
11B-411.1 General
Elevator operation shall be automatic....
-
Thresholds at Doorways
The 1991 Standards, at section 4.13.8, require the height of thresholds at doorways not to exceed ½ inch and thresholds at exterior sliding doors not to exceed ¾ inch....
-
(4) [sic] Thresholds at exterior doors
Subject to the exceptions for thresholds and changes in level at exterior areas constructed of impervious materials, the final Guidelines continue to specify that thresholds at exterior doors...
-
H2
Does the door to the toilet room provide at least 32 inches clear passage width when the door is open 90 degrees? [ADA Standards § 4.13.5] Yes No...
-
M2
Does the door to the toilet room provide at least 32 inches clear passage width when the door is open 90 degrees? [ADA Standards § 4.13.5] Yes No...
-
B. Measuring Clear Passage at Doors
Verifying the clear passage width at standard hinged doors requires an understanding of exactly where to measure....
-
Latches and Locks
However, non-fixed portions of locks and other operable parts, such as keys and access cards, are not required to comply (but those that do not require pinching or turning provide better...
-
(1)(e)
Door latches and hardware should be operable with one hand and should not require tight grasping, pinching, or twisting of the wrist....
-
Door King Inc. Versatility of the DKS 9100 Vehicular Sliding Gate Operator
Requires the Registered User plan or above. Login!
-
Door King Inc. Seamless Access Control with the DKS 9000 Vehicular Slide Gate Operator
Requires the Registered User plan or above. Login!
-
7b.
use one or both hands to fully operate the hardware?...
-
Section D: Entrances
opening (one door or one active leaf of a double door) at least 32"?...
-
11B-411.4.1 Car dimensions
Inside dimensions of elevator cars and clear width of elevator doors shall comply with Section 11B-407.4.1....
-
11B-216.4.1 Exit doors
Signs required by Chapter 10, Section 1013.4 at doors to exit passageways, exit discharge, and exit stairways shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5....
-
§382.105 What is the responsibility of carriers at foreign airports at which airport operators have responsibility for enplaning, deplaning, and connecting assistance?
by the airport operator to meet the requirements of this subpart....