382.105 What is the responsibility of carriers at foreign airports at which airport operators have responsibility for enplaning, deplaning, or connecting assistance?...
Search Results "Door Operator"
Commonly Searched Documents
-
382.105 What is the responsibility of carriers at foreign airports at which airport operators have responsibility for enplaning, deplaning, or connecting assistance?
-
Re: 404.2.6 Doors in Series and Gates in Series
My understanding is that it was written to keep wheelchair users from having to fight two doors at once. ...
- Besam SL500 A02 for sustainable automatic doors
-
M307 Operable Parts (Section-by-Section Analysis)
M307 in the final rule provides the technical criteria for operable parts used by patients to activate, deactivate, or adjust the diagnostic equipment....
-
§ 36.303(g)(9) Operational requirements
(9) Operational requirements....
-
D. Clear Floor Space
If there is a vestibule without fully automatic doors, is there a 30"x48" clear floor space where one can be outside the swing of a hinged door (i.e.: for out-swinging doors, at least 7'...
- Wagner Instruments Chatillon® DFE Digital Force Gauge
-
C. Clear Floor Space
When there is a vestibule into the public or employee restroom that does not have fully automatic doors, is there a 30"x48" clear floor space where one can be outside the swing of a hinged...
-
Can stair handrail extensions overlap door maneuvering clearances?
No, handrails and other elements cannot overlap door maneuvering clearances....
-
Viewing Scopes [1011.2, 1011.3, and 1011.8]
The other operable parts of viewing scopes, such as handles or levers, must be located between 15 and 48 inches above the ground and be operable using one hand without tightly grasping,...
- Sargent Wall and Frame Switch Interface for Door Operators
-
17. What should employers do to prevent and correct harassment?
17. What should employers do to prevent and correct harassment? Employers should make clear that they will not tolerate harassment based on disability or on any other basis. This...
-
Are redundant controls for an element required to comply?
If redundant controls, other than light switches, serve a single element, one control in each space is not required to comply. If a redundant control is located in a different space,...
- Automatic sliding door systems Besam SL500
-
11B-602.3 Operable parts
11B-602.3 Operable parts. Operable parts shall comply with Section 11B-309....
-
11B-813.2.1.3 Height and operation
Operable parts shall comply with Section 11B-309....
- CS SofStop Pocket Door Kit
-
11B-602.3 Operable parts
Operable parts shall comply with Section 11B-309....
- Wagner Instruments Force Ten ™ FDX
-
Doors [9.2.2(3), 9.4]
Doors [9.2.2(3), 9.4] Compliance with 4.13 is required for all doors and doorways designed to allow passage into and within all sleeping suites or other units required to be accessible...
-
F. Clear Width
Do all entry doors to accessible guestrooms and other interior doors (except doors on shallow closets) allow at least 32" of clear passage width to accommodate persons who use wheelchairs...
-
404.2.3 Doorways - Clear Width
Door openings shall provide a clear width of 32 inches (815 mm) minimum....
-
1132A.4.1 Thresholds
Thresholds at the primary entry and required exit doors shall be no higher than ½ inch (12.7 mm)....
- Mockett DH2 Door Handle Installation