Play-Land is Unity's 2 1/4", 2 1/2" and 2 3/4" thick rubberized safety surfacing, flooring and paver products that are made from 100% recycled tires and rubber granules mixed with a dye...
Search Results "Clear Floor Space"
Commonly Searched Documents
- Unity Surfacing Systems Play-Land Safety Surfacing
- Protege Fixed Wheelchair Lift 5442F
- Virtuoso Portable Wheelchair Lift 5460P
- TownSteel ED1100F Grade 1 Fire Rim Device
- Macro Supa-Trac Heavy Duty Ground Surface
- Inpro Corporation ENDURANT® Trench Drain Receptor
-
11B-233.3.4.1 Alterations to vacated buildings
Exception: Where any portion of a building’s exterior is preserved, but the interior of the building is removed, including all structural portions of floors and ceilings and a new building...
-
1136A.2 Switch and control heights
located no more than 48 inches (1219 mm) measured from the top of the outlet box nor less than 15 inches (381 mm) measured from the bottom of the outlet box to the level of the finished floor...
-
1117B.1, Item 5
The bubbler outlet orifice shall be located within 6 inches (152mm) of the front edge of the drinking fountain and within 36 inches (914 mm) of the floor....
-
1117B.1, Item 4
The bubbler outlet orifice shall be located within 6 inches (152mm) of the front edge of the drinking fountain and within 36 inches (914 mm) of the floor....
-
Wheelbase Definition
Wheelbase Definition For the purpose of this analysis, wheelbase is defined as the distance from the center of the primary drive wheel to the center of the caster measured parallel to the floor...
-
Which Circulation Paths Are Usable Circulation Paths?
In addition, simple floor plans of the building that show the locations of and routes to usable circulation paths should be available and given to visitors with limited mobility when they...
-
3.3.15.1 Forward reach – unobstructed
of the power chair users and 48% of the scooter users could reach beyond their mobility device or foot for at least one point between 600 mm (23.6 in.) and 1100 mm (43.3 in.) from the floor...
-
Existing Elevators (Alterations)
Certain alterations or additions to a facility may trigger the requirement for an accessible route between floors, including: where stairs or escalators are added in an alteration...
-
11B-233.3.4.1 Alterations to vacated buildings
Exception: Where any portion of a building’s exterior is preserved, but the interior of the building is removed, including all structural portions of floors and ceilings and a new building...
-
1136A.2 Switch and control heights
located no more than 48 inches (1219 mm) measured from the top of the outlet box nor less than 15 inches (381 mm) measured from the bottom of the outlet box to the level of the finished floor...
-
1136A.2 Switch and control heights
located no more than 48 inches (1219 mm) measured from the top of the outlet box nor less than 15 inches (381 mm) measured from the bottom of the outlet box to the level of the finished floor...
-
ADA Standards for Accessible Design Pocket Guide: ADA Standard Section 2010
The complete guide to the 2010 ADA Standards for Accessible Design with notes provided by national accessibility experts Evan Terry Associates
-
Evaluation of transfers
Our results also showed that in terms of minimum space required for the transfer, the guidelines are insufficient (Table 12)....
-
1002.2 Accessible Routes
In most cases, this will be limited to areas where the accessible route leads directly to the amusement ride and where there are space limitations on the ride, not the queue line....
-
F215.1 General
Unlike audible alarms, visible alarms must be located within the space they serve so that the signal is visible....
-
Accessible Routes to Press Boxes
An accessible route is not required to press boxes with 500 square feet or less of aggregate space that are located on bleachers with entrances on only one level (Exception 1)....
-
Table Surface Height
The Board has not revised the specified height for dining and work surfaces or the minimum clearances for knee and toe space required below since it believes further research is needed on...
-
604.5.2 Rear Wall
The rear grab bar shall be permitted to be 24 inches (610 mm) long minimum, centered on the water closet, where wall space does not permit a length of 36 inches (915 mm) minimum due to the...