located no more than 48 inches (1219 mm) measured from the top of the outlet box nor less than 15 inches (381 mm) measured from the bottom of the outlet box to the level of the finished floor...
Search Results "Clear Floor Space"
Commonly Searched Documents
-
1136A.2 Switch and control heights
-
1117B.1, Item 5
The bubbler outlet orifice shall be located within 6 inches (152mm) of the front edge of the drinking fountain and within 36 inches (914 mm) of the floor....
-
1117B.1, Item 4
The bubbler outlet orifice shall be located within 6 inches (152mm) of the front edge of the drinking fountain and within 36 inches (914 mm) of the floor....
-
Wheelbase Definition
Wheelbase Definition For the purpose of this analysis, wheelbase is defined as the distance from the center of the primary drive wheel to the center of the caster measured parallel to the floor...
-
Which Circulation Paths Are Usable Circulation Paths?
In addition, simple floor plans of the building that show the locations of and routes to usable circulation paths should be available and given to visitors with limited mobility when they...
-
3.3.15.1 Forward reach – unobstructed
of the power chair users and 48% of the scooter users could reach beyond their mobility device or foot for at least one point between 600 mm (23.6 in.) and 1100 mm (43.3 in.) from the floor...
-
Existing Elevators (Alterations)
Certain alterations or additions to a facility may trigger the requirement for an accessible route between floors, including: where stairs or escalators are added in an alteration...
-
11B-233.3.4.1 Alterations to vacated buildings
Exception: Where any portion of a building’s exterior is preserved, but the interior of the building is removed, including all structural portions of floors and ceilings and a new building...
-
1136A.2 Switch and control heights
located no more than 48 inches (1219 mm) measured from the top of the outlet box nor less than 15 inches (381 mm) measured from the bottom of the outlet box to the level of the finished floor...
-
1136A.2 Switch and control heights
located no more than 48 inches (1219 mm) measured from the top of the outlet box nor less than 15 inches (381 mm) measured from the bottom of the outlet box to the level of the finished floor...
-
FIELD DATA COLLECTION PLAN
Space required for three-point turn. Lateral operating space (sweep width). Turning radii. Acceleration capabilities. Speed....
- Assisted Living Directory - Michigan Assisted Living Facilities & Adult Foster Care for Seniors
- Easter Seals Southwest Florida
-
Are there good examples of Title III Compliance for making goods and services accessible?
This answer was so common that it seemed clear to me that it had been professionally coached. I also know that the answer is not altogether correct....
- Inclusion Solutions Pakflatt® Franklin® Voting Booth
- Bradley Advocate AV-Series AV30 Lavatory, Soap & Hand Dryer
- American Specialties 9012 Surface Mounted Baby Changing Station
- Locus Labs Inc. LocusMaps SDK
-
National Council on Independent Living
The surface height we had recommended historically was 17 to 19 inches above the floor, which has been around for years in existing Standards....
-
Scoping for timeshare or condominium hotels. (Section-by-Section Analysis)
In a newly constructed condominium that has three floors with units dedicated to be sold solely as residential housing and three floors with units that may be used as residences or hotel...
-
Robert Dupuy, IALD, LC. Problems and Solutions
I mean, I do on a regular basis ambient lighting levels in office spaces that are 20-foot candles and have to be supplemented with task lights because 20- foot candles is simply not enough...
-
11B-206.4.10 Medical care and long-term care facilities
interpretation of Subsection 11B-206.4.10: Section 11B-206.4.10 requires a minimum of one accessible entrance to be provided with weather protection, passenger loading zone, and vehicle pull-up space...