(10) Platform movement. No part of the platform shall move at a rate exceeding 6 inches/second during lowering and lifting an occupant, and shall not exceed 12 inches/second during...
Search Results "Vehicle Hand Control"
Commonly Searched Documents
-
§ 38.83(b)(10) Platform movement
-
§ 38.83(b)(11) Boarding direction
(11) Boarding direction. The lift shall permit both inboard and outboard facing of wheelchairs and mobility aids.
-
707.5.1 User Control
Volume control shall be provided for the speech function....
-
707.5.1 User Control
Volume control shall be provided for the speech function....
-
402.2.4 User Control
Speech output for any single function shall be automatically interrupted when a transaction is selected. Speech output shall be capable of being repeated and paused.
-
§ 38.159(b)(7) Platform gaps
When the platform is at vehicle floor height with the inner barrier (if applicable) down or retracted, gaps between the forward lift platform edge and the vehicle floor shall not exceed...
-
On existing locations when we add an EV station as van accessible how do we address taking two spaces from the facility (losing a space) and then not having the mandatory spaces remaining for the facility?
Consistent with the state’s policies on electric vehicles, DSA encourages city and county officials to recognize the necessary impact of EVCS and adopt responsive ordinances consistent with...
-
We are also being asked to show the future space for the 1 Van accessible EV space that would be required in the future, if the equipment was installed. And due to the requirement for the access aisle beside this space, in the future it would be converted to an access aisle resulting in the loss of one parking space. As this project is right at the required number of parking spaces per zoning, it is not acceptable to the zoning reviewer to sign off on a plan that shows a “future access aisle for future EV van accessible charging space,” as they are approving the loss of a parking space, even though this would not happen until a future condition, upon which I assume there would be some review process for installation of EV charging equipment. What is the appropriate path forward in this situation?
Consistent with the state’s policies on electric vehicles, DSA encourages city and county officials to recognize the necessary impact of EVCS and adopt responsive ordinances consistent with...
-
Delta 3-Setting 2-Port Diverter Trim - Model T11859
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Delta 3-Setting 2-Port Diverter Trim - Model T11861
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Delta 3-Setting 2-Port Diverter Trim - Model T11864
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-408.4.6 Car controls
Elevator car controls shall comply with Section 11B-407.4.6. Control panels shall be centered on a side wall....
-
11B-408.4.6 Car controls
Elevator car controls shall comply with Section 11B-407.4.6. Control panels shall be centered on a side wall....
-
11B-408.4.6 Car controls
Elevator car controls shall comply with Section 11B-407.4.6. Control panels shall be centered on a side wall....
-
Currently, the DCFC time limit is 30 minutes maximum. New larger battery capacity will take longer to get 80% charge – i.e. Chevy Bolt EV, Tesla Model 3, 2018 Nissan LEAF, etc. Can we reconsider the time limit?
Where DCFC or any other type of charging is intended for use longer than 30 minutes, EVCS may be provided in regular parking-style vehicle spaces....
-
Dyson Airblade V Hand Dryer Revit Model
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Dyson Airblade V Hand Dryer SketchUp Model
Requires the Premium User plan or above. (Login or upgrade your account!)
- Georgia-Pacific enMotion® White Marble Automated Touchless Soap and Sanitizer Dispenser
-
704.3 Volume Control Telephones
704.3 Volume Control Telephones. Public telephones required to have volume controls shall be equipped with a receive volume control that provides a gain adjustable up to 20 dB minimum....
-
Dyson Airblade V Hand Dryer Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Dyson Airblade V Hand Dryer Front Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
12148(b)(2) Historic trains
(2) Historic trains In order to comply with paragraph (1) with respect to the remanufacture of a vehicle of historic character which is to be used on a segment of a light or rapid rail...
-
§ 38.73(d)(1) Requirements
The design of level-entry vehicles shall be coordinated with the boarding platform or mini-high platform design so that the horizontal gap between a vehicle at rest and the platform shall...
-
§ 38.23(d)(4) Orientation
front of the vehicle....