Objects with leading edges more than 27 inches (685 mm) and not more than 80 inches (2030 mm) above the finish floor or ground shall protrude 4 inches (100 mm) maximum horizontally into...
Search Results "Horizontal Dispersion"
Commonly Searched Documents
-
307.2 Protrusion Limits
-
11B-1002.4.3 Gaps
coordinated so that, when amusement rides are at rest in the load and unload position, the vertical difference between the floors shall be within plus or minus 5/8 inches (15.9 mm) and the horizontal...
-
11B-307.2 Protrusion limits
Objects with leading edges more than 27 inches (686 mm) and not more than 80 inches (2032 mm) above the finish floor or ground shall protrude 4 inches (102 mm) maximum horizontally into...
-
307.2 Protrusion Limits
Objects with leading edges more than 27 inches (685 mm) and not more than 80 inches (2030 mm) above the finish floor or ground shall protrude 4 inches (100 mm) maximum horizontally into...
-
1002.4.3 Gaps
coordinated so that, when amusement rides are at rest in the load and unload position, the vertical difference between the floors shall be within plus or minus 5/8 inches (16 mm) and the horizontal...
-
602.6 Water Flow
The angle of the water stream shall be measured horizontally relative to the front face of the unit....
-
Transfer Supports Location and Configuration M301.3 and M302.3
The shape (contours and curves along length for ergonomics, not cross sectional profile) was kept open to give manufacture flexibility in the design as the direction of positioning (i.e. horizontal...
-
1002.4.3 Gaps
coordinated so that, when amusement rides are at rest in the load and unload position, the vertical difference between the floors shall be within plus or minus 5/8 inches (16 mm) and the horizontal...
-
Water closet
In the horizontal or down position, grab bars on both sides of the toilet would permit individuals requiring assistance to maintain balance while clothing was removed or replaced....
-
Slope [§405.2] and Cross Slope [§405.3]
Slope [§405.2] and Cross Slope [§405.3] Slope represents the proportion of vertical rise to horizontal length and is specified in the Standards as a ratio (e.g., 1:12)....
-
Tactile and Visual Signs [ADA Standards §216.2, §216.4.1]
(An exit passageway is a horizontal component of an exit that is separated from interior building spaces by fire-resistance-rated construction that leads to the exit discharge or public...
-
11B-1002.4.3 Gaps
coordinated so that, when amusement rides are at rest in the load and unload position, the vertical difference between the floors shall be within plus or minus 5/8 inches (15.9 mm) and the horizontal...
-
11B-1002.4.3 Gaps
coordinated so that, when amusement rides are at rest in the load and unload position, the vertical difference between the floors shall be within plus or minus 5/8 inches (15.9 mm) and the horizontal...
-
ICC/IBC: ADA Standard Section 105.2.4
Section 105.2.4 of the ADA Standards cover references to the International Code Council (ICC) and the International Building Code (IBC).
-
11B-608.6 Shower spray unit and water
Each shower head shall be installed so it can be operated independently of the other and shall have swivel angle adjustments, both vertically and horizontally....
- Proline Drain: Quick Drain USA - Side Waste Outlet Tub to Shower Conversion
- AquaTrek2 ADA Ladder System
-
Ground Level Play Components: ADA Standard Section 240.2.1
Section 240.2.1 covers scoping requirements in the current ADA Standards for ground level play components.
-
11B-240.2.1 Ground level play components
Where two or more required ground level play components are provided, they shall be dispersed throughout the play area and integrated with other play components....
-
M301.3 Transfer Supports
Height: Located no less than 6 inches (150 mm) and no more than 19 inches (482 mm) above the patient support surface Horizontal Distance from Transfer Surface: No more than 3 inches (...
-
Section 35.151(g)(3)
The use of temporary platforms has the effect of neutralizing dispersion and other seating requirements (e.g., line of sight) for wheelchair spaces and companion seats. Cf....
-
602.6 Water Flow
The angle of the water stream shall be measured horizontally relative to the front face of the unit....
-
1127B.5, Item 4
each curb ramp over its full width to permit safe egress from the ramp surface, or the slope of the fanned or flared sides of the curb ramp shall not exceed one unit vertical in 12 units horizontal...
-
602.6 Water Flow
The angle of the water stream shall be measured horizontally relative to the front face of the unit....