In addition to the provisions of Section 1.1.8.1 of this part, the provisions of this section shall apply to a city, county, and cities and counties adopting local energy standards applicable...
Search Results "1991 Standards"
-
1.1.8.2 Locally adopted energy standards - California Energy Code, Part 6.
-
Alterations to Primary Function Areas
202.4 restates a current requirement under title III, and therefore represents no change for title III facilities or for those title II facilities that have elected to comply with the 1991...
-
Platform Lifts in Transient Lodging Guest Rooms and Dwelling Units
The 1991 Standards, at section 4.1.3(5), exception 4, and the 2010 Standards, at sections 206.7 and 206.7.6, both limit the locations where platform lifts are permitted to be used as part...
-
202.3.1 Prohibited Reduction in Access
(c) If the 2010 Standards reduce the technical requirements or the number of required accessible elements below the number required by the 1991 Standards, the technical requirements or the...
-
Vehicular Route Exceptions—Sections 206.2.1 and 206.2.2 of the 2010 Standards
The 2010 Standards contain an exception for accessibility at site arrival points which provides that an ‘‘accessible route shall not be required between site arrival points and the building...
- Stanley QTL 200 Series Grade 2 Standard Duty Tubular Locks
-
MAKING THE BUILT ENVIRONMENT ACCESSIBLE
The ADA’s regulations and the ADA Standards for Accessible Design, originally published in 1991, set the standard for what makes a facility accessible....
-
Guest Rooms with Communication Features
The revisions at section 224.4 of the 2010 Standards effect no substantive change from the 1991 Standards with respect to the number of guest rooms required to provide communication features...
-
3. Element by Element Safe Harbor
The rule includes a general "safe harbor" under which elements in covered facilities that were built or altered in compliance with the 1991 Standards or the UFAS would not be required to...
- American Standard Colony Choice 1-Handle Kitchen Faucet 4175.700
-
Toilet Paper Dispensers
In the 1991 Standards the location of the toilet paper dispenser is determined by the centerline and forward edge of the dispenser....
-
Section 35.151(d) Scope of Coverage (Section-by-Section Analysis)
Although the Department often chooses to use the requirements of the 1991 Standards as a guide to determining when and how to make equipment and furnishings accessible, those determinations...
- American Standard Monterrey 8" Widespread Faucet, Rigid/Swivel Gooseneck Spout
- H2O Innovations AQUA STEP ADA
-
Mono Jacks, Sound Pressure, Etc
Section 4.33.7 of the 1991 Standards does not contain specific technical requirements for assistive listening systems....
-
Ambulatory Accessible Toilet Compartments
Section 213.3.1 of the 2010 Standards requires multi-user men’s toilet rooms, where the total of toilet compartments and urinals is six or more, to contain at least one ambulatory accessible...
-
§ 35.150(b)(2)(i) Safe harbor
that have not been altered in existing facilities on or after March 15, 2012 and that comply with the corresponding technical and scoping specifications for those elements in either the 1991...
-
Section 35.151(i) Curb Ramps (Section-by-Section Analysis)
Both the 1991 Standards and the proposed standards provide technical guidance for the installation of curb ramps....
-
212 and 606 Kitchens, Kitchenettes, Lavatories, and Sinks
212 and 606 Kitchens, Kitchenettes, Lavatories, and Sinks The 1991 Standards, at sections 4.24, and 9.2.2(7), contain technical requirements for sinks and only have specific scoping requirements...
-
11B-202.3.1 Prohibited reduction in access
(c) If the 2010 Standards reduce the technical requirements or the number of required accessible elements below the number required by the 1991 Standards, the technical requirements or the...
-
Multiple Single-User Toilet Rooms
Where multiple single-user toilet rooms are clustered in a single location, fifty percent (50%), rather than the one hundred percent (100%) required by the 1991 Standards, are required to...
-
§ 36.304(d)(2)(iii)
., elements for which there are neither technical nor scoping specifications in the 1991 Standards), and therefore those elements must be modified to the extent readily achievable to comply...
-
11B-202.3.1 Prohibited reduction in access
(c) If the 2010 Standards reduce the technical requirements or the number of required accessible elements below the number required by the 1991 Standards, the technical requirements or the...