4.31.5 Hearing Aid Compatible and Volume Control Telephones Required by 4.1
-
Auxiliary Aids and Services
Auxiliary Aids and Services: If auxiliary aids and services are requested by guests, meeting organizers will need to address before the meeting takes place how to provide such services...
-
M301 Diagnostic Equipment used by Patients in a Supine, Prone, or Side-lying Position (Section-by-Section Analysis)
M301 in the final rule establishes the technical criteria for diagnostic equipment used by patients in a supine, prone, or side-lying position such as, examination tables, imaging tables...
-
5.4.2.2 Transfer and Positioning Support Length for Imaging Equipment with Transfer Surfaces
5.4.2.2 Transfer and Positioning Support Length for Imaging Equipment with Transfer Surfaces....
-
2. Different Types of Auxiliary Aids and Services
Here are some examples of different auxiliary aids and services that may be used to provide effective communication for people with disabilities. ...
-
Turning Space: ADA Standard Section 1010.1
A circular turning space 60 inches (1525 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....
-
11B-1010.1 Turning space
A circular turning space 60 inches (1524 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....
-
11B-1010.1 Turning space
A circular turning space 60 inches (1524 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing positions....
-
5.4.2.2 Transfer and Positioning Support Length Recommendations for Imaging Equipment with Transfer Surfaces
along the long dimension of the surface on which patients are positioned in the supine, prone, or side-lying position (see Figure 5.2.1.4)....
-
1. Providing Equal Access With Auxiliary Aids and Services
These different ways are provided through “auxiliary aids and services.” ...
-
5.4.3.1 Positioning Support Height Recommendation for Imaging Equipment with Transfer Surfaces
5.4.3.1 Positioning Support Height Recommendation for Imaging Equipment with Transfer Surfaces For imaging equipment with transfer surfaces, the Committee recommends a positioning support...
-
Transfer Surface Size: Equipment Used by Patients in Supine, Prone, or Side-Lying Position (M301.2.2)
which patients who use mobility devices or aids transfer when moving onto and off of the equipment) to be 30 inches wide minimum and 15 inches deep minimum....
- Midmark 625 Barrier-Free® Power Examination Table
-
Hearing Aid Compatible and Volume Control Telephones [4.13.5] [sic]
control and be hearing aid compatible....
- Midmark 623 Barrier-Free® Power Examination Table
-
Auxiliary Aids and Services
Often ensuring effective communication requires public entities to provide “auxiliary aids and services” which may include the following: For people who are deaf or have hearing loss:...
-
17. Q: Can we exclude children with HIV or AIDS from our program to protect other children and employees?
Q: Can we exclude children with HIV or AIDS from our program to protect other children and employees? A: No. Centers cannot exclude a child solely because he has HIV or AIDS....
-
Supports (M301.3, M302.3, and M305.2)
[to] increase safety and assist patients in transferring on and off, positioning or repositioning their bodies, and maintaining static position.” See ANSI/AAMI HE 75, section 16.4.6....
-
Location and Size
The side rails can also be relocated along the table surface (from foot-end to head-end) for patients to position or reposition their bodies, and to maintain static positions....
-
M101.2 Application
is designed to support: • Equipment used by patients in a supine, prone, or side-lying position (see M301); • Equipment used by patients in a seated position (see M302); • Equipment...
-
b. Positioning Supports
The Access Board noted in the MDE NPRM preamble that it was considering adding positioning supports to the final rule and sought public input with question 24 on whether positioning supports...
-
243 Shooting Facilities with Firing Positions
243 Shooting Facilities with Firing Positions Sections 243 and 1010 of the 2010 Standards require an accessible turning space for each different type of firing position at a shooting...
-
Transfer Surface Height (M301.2.1 and M302.2.1)
The transfer surface height is also critical for patients who use mobility aids such as walkers and canes and may find it difficult to get up onto or down from an examination chair or table...
- The UpScale Medical Exam Table