Section 213.3.4 covers scoping requirements in the current ADA Standards for lavatories.
Search Results "Lavatory"
-
Lavatories: ADA Standard Section 213.3.4
-
604.8.1.6 Lavatory
604.8.1.6 Lavatory....
-
606 Lavatories and Sinks
606 Lavatories and Sinks...
-
606.1 General
Lavatories and sinks shall comply with 606. Advisory 606.1 General. If soap and towel dispensers are provided, they must be located within the reach ranges specified in 308....
-
607.2 Clearance
A lavatory complying with 606 shall be permitted at the control end of the clearance....
-
608.2.2.1 Clearance
EXCEPTION: A lavatory complying with 606 shall be permitted on one 30 inch (760 mm) wide minimum side of the clearance provided that it is not on the side of the clearance adjacent to the...
-
1134A.5, Item 1
The area under a lavatory, located at the control end of the tub, may be included in the clear floor space provided the lavatory is 19 inches (483 mm) maximum deep, and the knee and toe...
-
1134A.8 Lavatories, vanities, mirrors and towel fixtures
A clear maneuvering space at least 30 inches by 48 inches (762 mm by 1219 mm) shall be provided at lavatories and shall be centered on the lavatory. 3. Cabinets....
-
1134A.8 Lavatories, vanities, mirrors and towel fixtures
Bathrooms or powder rooms required to be accessible shall have at least one accessible lavatory....
-
1134A.8, Item 2
A clear maneuvering space at least 30 inches by 48 inches (762 mm by 1219 mm) shall be provided at lavatories and shall be centered on the lavatory....
-
1134A.8, Item 4
4. Knee and toe space. Knee and toe space shall be provided by one of the following:
-
1134A.8, Item 4.1
The space beneath the lavatory shall be left clear and unobstructed;...
-
1134A.8, Item 4.2
Any cabinet beneath the lavatory shall be removable without the use of specialized knowledge or specialized tools; or...
-
1134A.8, Item 4.3
Doors to the cabinet beneath the lavatory shall be removable or openable to provide the required unobstructed knee and toe space....
-
1134A.8, Item 6
Water supply and drain pipes under lavatories shall be insulated or otherwise covered to protect against contact. There shall be no sharp or abrasive surfaces under lavatories....
-
1134A.8, Item 7
Lavatory faucet controls. Faucet controls and operation mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist....
-
1134A.8, Item 8
8. Mirrors and towel fixtures. Where mirrors or towel fixtures are provided they shall be mounted with the bottom edge no higher than 40 inches (1016 mm) from the floor.
-
Sinks [F212.3, Exception 2]
Lavatories must comply with the technical requirements for lavatories in section 606 of the ABA Standards....
-
606 Lavatories and Sinks
-
606.1 General
Lavatories and sinks shall comply with 606. Advisory 606.1 General. If soap and towel dispensers are provided, they must be located within the reach ranges specified in 308....
-
607.2 Clearance
A lavatory complying with 606 shall be permitted at the control end of the clearance....
-
608.2.2.1 Clearance
EXCEPTION: A lavatory complying with 606 shall be permitted on one 30 inch (760 mm) wide minimum side of the clearance provided that it is not on the side of the clearance adjacent to the...
-
11B-102 Dimensions for adults and children.
In addition, this chapter includes technical requirements based on children’s dimensions and anthropometrics for drinking fountains, water closets, toilet compartments, lavatories and sinks...