(v) Vanities and lavatories are installed with the centerline of the fixture a minimum of 1'3" horizontally from an adjoining wall or fixture....
Search Results "Lavatory"
Commonly Searched Documents
-
7(2)(b)(v)
-
11B-809.10.8.6 Controls
Faucet controls and operating mechanisms shall comply with Section 11B-309.4.
-
11B-809.10.8 Lavatories, vanities, mirrors and towel bars
Bathing rooms or powder rooms required to comply with Section 11B-809.10 shall provide lavatories complying with this section....
-
11B-809.10.5.1 Clear floor space
The area under a lavatory, located at the control end of the tub, shall be permitted to encroach on the clear floor space provided the lavatory is 19 inches (483 mm) maximum in depth, and...
-
Sinks [F212.3, Exception 2]
Lavatories must comply with the technical requirements for lavatories in section 606 of the ABA Standards....
-
Sinks [4.24]
Sinks [4.24] ADAAG provides technical specifications for both "lavatories" and "sinks."...
-
Clear Floor Space [4.19.3]
Recommendations:Consider locating towel dispensers within reach from the lavatory so that people can dry their hands before maneuvering wheelchairs....
- Just Manufacturing Oval Lavatory Group Drop-in Sink with Overflow
-
M9
Does the lavatory have at least a 29-inch-high clearance under the front edge and the top of the rim no more than 34 inches above the floor?...
- Willoughby Industries CEL-Multi-Station Lavatory Series
-
1134A.8, Item 5
The finished floor beneath the lavatory shall be extended to the wall....
-
1134A.8, Item 5
The finished floor beneath the lavatory shall be extended to the wall....
-
4.19.5 Faucets
Faucets shall comply with 4.27.4. Lever-operated, push-type, and electronically controlled mechanisms are examples of acceptable designs. If self-closing valves are used the faucet...
-
Faucets [4.19.5]
Faucets [4.19.5] Faucets must: be within reach range be automatic or, if hand operated, operable with one hand operate without tight grasping, pinching,...
-
4.19.5 FAUCETS
Faucets shall comply with 4.27.4. Lever-operated, push-type, and electronically controlled mechanisms are examples of acceptable designs. Self-closing valves are allowed if the...
-
11B-604.3.2 Overlap
Exception: In residential dwelling units, a lavatory complying with Section 11B-606 shall be permitted on the rear wall 26 inches (660 mm) minimum from the water closet centerline to allow...
-
I. Public Toilet Rooms
Public Toilet Rooms: (1) In all public and common use toilet rooms throughout the Hotel and the Tower, Defendants will provide at least one lavatory with a counter-top that is 34 inches...
-
606.2 Clear Floor Space (Exception 3)
606.2 Clear Floor Space (Exception 3) This section requires clear floor space positioned for a forward approach and knee and toe clearance to be provided at lavatories and sinks....
-
1134A.8, Item 6
Water supply and drain pipes under lavatories shall be insulated or otherwise covered to protect against contact. There shall be no sharp or abrasive surfaces under lavatories....
-
1134A.8, Item 6
Water supply and drain pipes under lavatories shall be insulated or otherwise covered to protect against contact. There shall be no sharp or abrasive surfaces under lavatories....
-
606.1 General
Lavatories and sinks shall comply with 606. Advisory 606.1 General. If soap and towel dispensers are provided, they must be located within the reach ranges specified in 308....
-
606.1 General
Lavatories and sinks shall comply with 606. Advisory 606.1 General. If soap and towel dispensers are provided, they must be located within the reach ranges specified in 308....
-
1134A.8, Item 7
Lavatory faucet controls. Faucet controls and operation mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist....
-
606.1 General
Lavatories and sinks shall comply with 606. Advisory 606.1 General. If soap and towel dispensers are provided, they must be located within the reach ranges specified in 308....