All walks, halls, corridors, aisles, skywalks, tunnels, and other spaces that are part of an accessible route shall comply with 4.3....
Search Results "Lavatory Clear Floor Space"
-
4.3.1* General
-
M305.3.1.1 Horizontal Position
The length of gripping surfaces on horizontal standing supports shall be 4 inches (100 mm) minimum except for diagnostic equipment containing a wheelchair space which shall comply with M305.3.1.2...
-
4.3.2(4)
(4) An accessible route shall connect at least one accessible entrance of each accessible dwelling unit with those exterior and interior spaces and facilities that serve the accessible dwelling...
-
705.1.3 Contrast
Figure 705.1 Size and Spacing of Truncated Domes...
- Kohler San Tropez® Vertical Spray Bidet with 4 Faucet Holes
-
Handrail Extensions
Where handrail extensions are provided, they do not need to be parallel with the ground or floor surface, since the surface may be moving due to water conditions....
-
4.10.14* Emergency Communications
The highest operable part of a two-way communication system shall be a maximum of 48 in (1220 mm) from the floor of the car....
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Side Approach Manual Wheelchair
chair users represented as the percentage of users able to retrieve and place a 5 lb object on a target shelf in the lateral or sideways reach direction for a given (a) height from the floor...
- Arctic Access - Kotzebue, AK
-
§ 37.91(a)
(a) As soon as practicable, but in no event later than July 26, 1995, each person providing intercity rail service shall provide on each train a number of spaces—...
-
Picnic Unit
An outdoor space within a picnic area or facility that is designed and constructed for picnicking and that contains one or more constructed features such as picnic tables, grills, and other...
-
4.1.2(12)
(12) Controls and operating mechanisms in accessible spaces, along accessible routes, or as parts of accessible elements (for example, light switches and dispenser controls) shall comply...
-
1009.6.1 Travel distance
The maximum travel distance from any accessible space to an area of refuge shall not exceed the exit access travel distance permitted for the occupancy in accordance with Section 1017.1....
-
Accessible Passenger Loading Zones at Medical Care and Long-Term Care Facilities
The scope of this requirement was not clear to commenters who asked whether the reference to medical care facilities included doctors’ and dentists’ offices, clinics, and similar types of...
-
Accessibility Evaluation Surveys
For example, check doorways to see whether they have at least 32 inches (815 millimeters) of clear width (figure 14)....
-
"User Friendly" Guidelines
These commenters requested that the final Guidelines be clear, concise and "user friendly"....
-
Accessible Routes within a Building or Facility
At least one accessible route must connect all accessible spaces and elements. If a circulation path is interior, the accessible route also must be interior....
-
11B-502.3.3 Marking
Asphalt is often the parking surface material used at accessible parking spaces. Asphalt is generally considered to be fairly dark in appearance....
-
11B-809.8.3 Door maneuvering clearance.
A 39 inch (991 mm) minimum length is allowed at interior doors when a clear opening width of 34 inches (864 mm) minimum is provided....
- Proline Drain
-
11B-217.4 TTYs
Separate requirements are provided based on the number of public pay telephones provided at a bank of telephones, within a floor, a building, or on a site....
- VGo Telepresence Robot
- Nana Wall Systems, Inc. High Velocity Hurricane Zone Folding Glass Walls SL73
- Cavity Sliders USA Inc. CL100 ADA Privacy Lever Lock for Pocket Doors



