Search Results "Medical Exam"
Commonly Searched Documents
- Stanley Access Technologies Dura-Care 7000 Manual Door System 3.02 DC70-SS
-
Stanley Access Technologies Dura-Care 7000 Manual Door System 3.50 DC7-TD
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Stanley Access Technologies Dura-Care 7000 Manual Door System 3.03 DC70TL-BP
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Horton Automatics Profiler® Smoke-Rated Telescoping ICU/CCU Sliding Door Model
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Horton Automatics ICU/CCU Bi-Fold/Bi-Swing™ Door System
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Stanley Access Technologies Dura-Care 7000 Manual Door System 3.04 DC70TL-SS
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Stanley Access Technologies Dura-Care 7200 Manual Sliding Door
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Stanley Access Technologies Dura-Care Manual Sliding Door
Requires the Premium User plan or above. (Login or upgrade your account!)
- Stanley Access Technologies Dura-Care 7000 Manual Door System
- Stanley Access Technologies Dura-Care 7200 Manual Sliding Door
- ADA25: #9 of 25 -- Hospital: Interpreters
-
3. Exception to Ramp Running Slope
The space constraints affect the desirability of accessible scales since space is often expensive and tight in many medical facilities....
-
2. c. REACH RANGES
The maximum reach ranges (detailed below) should be considered in the placement of information brochures, magazines and other items located in medical office lobbies, reception, and waiting...
-
II. ENFORCING THE ADA PART 2
Accessible Medical Equipment and Facilities The use of medical equipment is vital to the provision of medical care....
-
M303.3.3.2 Cross Slope
The cross slope of ramp runs shall not be steeper than 1:48.
-
M303.3.3 Ramped
Changes in level greater than ½ inch (13 mm) high shall be ramped and shall comply with M303.3.3.
-
C. M303 Diagnostic Equipment Used by Patients Seated in a Wheelchair
M303 contains the technical requirements for diagnostic equipment used by patients seated in wheelchairs. In the final rule the Access Board made four significant changes to this...
-
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms.
-
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height
5.8.1.2.4 Edge Protection on Platforms 1½ inches or less in Height. Edge protection is not required on platforms 1 ½ inches or less in height.
-
M303.2.5 Surfaces (Section-by-Section Analysis)
The MDE NPRM proposed to require diagnostic equipment used by patients seated in a wheelchair to provide a wheelchair space with a surface that does not slope more than 1:48 in any...
-
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms
5.8.1.2 Entry to Wheelchair Spaces on Raised Platforms Recommendations Description: Entry to wheelchair spaces on raised surfaces greater than ¼ inch in height requires a...
-
5.8.1.2.2 Single Ramped Entry - Edge Protection on the Platform and Platform Sides Recommendations
5.8.1.2.2 Single Ramped Entry - Edge Protection on the Platform and Platform Sides Recommendations The Committee recommends a two-inch high edge protection on the back of the...
-
5.8.1.2.1 Ramped Entry Slope
5.8.1.2.1 Ramped Entry Slope. Raised platforms should have a ramp with slopes that do not exceed the following: Rise 0 to 1 ½ inches – 1:2 Slope Rise >1 ½ to 2 ½ inches – 1:8...
-
5.9.2 Standing Supports on Ramped Entry Raised Platforms with Wheelchair Spaces
5.9.2 Standing Supports on Ramped Entry Raised Platforms with Wheelchair Spaces.