The Access Board is considering adding exceptions in the final standards to the minimum width in M303.2.2 and the minimum depth in M303.2.3 for diagnostic equipment with wheelchair...
Search Results "Medical Exam"
Commonly Searched Documents
-
Exceptions Considered for Wheelchair Spaces on Raised Platforms
-
Chapter M1 Application and Administration
[See subsections ...]
-
11B-805.2 Patient bedrooms and resident sleeping rooms
Patient bedrooms and resident sleeping rooms required to provide mobility features shall comply with Section 11B-805.2. ETA Editor's Note According to the Office of Statewide...
-
M303.2.6 Edge Protection
Where wheelchair spaces are provided on a platform raised more than 1 ½ inches (38 mm) in height, edge protection 2 inches (51 mm) high minimum measured from the surface of the...
-
11B-805.2 Patient bedrooms and resident sleeping rooms
Patient bedrooms and resident sleeping rooms required to provide mobility features shall comply with Section 11B-805.2. ETA Editor's Note According to the Office of...
-
Section 36.309 Examinations and Courses (Preamble, Section-by-Section Analysis)
Examinations covered by this section would include a bar exam or the Scholastic Aptitude Test prepared by the Educational Testing Service....
- Stanley Access Technologies Dura-Care 7000 Manual Door System
- Stanley Access Technologies Dura-Care 7200 Manual Sliding Door
- Defining and Delivering Disability-Competent Care - The Care Coordination Relationship
-
11B-223.1 General
In licensed medical care facilities and licensed long-term care facilities where the period of stay exceeds twenty-four hours, patient bedrooms or resident sleeping rooms shall be provided...
-
11B-223.1 General
In licensed medical care facilities and licensed long-term care facilities where the period of stay exceeds twenty-four hours, patient bedrooms or resident sleeping rooms shall be provided...
-
11B-223.1 General
In licensed medical care facilities and licensed long-term care facilities where the period of stay exceeds twenty-four hours, patient bedrooms or resident sleeping rooms shall be provided...
-
M302.2.2 Sunset
The low transfer position height, Item A of M302.2.1, shall cease to have effect on [Insert date 5 years after date of publication in the Federal Register]. [sic]
-
M302.2.1 Adjustability
Transfer surfaces shall be adjustable in height measured from the floor to the top of the uncompressed transfer surface and shall provide the following: A. A low transfer position...
-
M302.2.1 Adjustability (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface height range for diagnostic equipment used by patients in a seated position of 17 inches minimum and 19 inches maximum. The Access Board...
-
M302.2.2 Sunset Provision (Section-by-Section Analysis)
As discussed in Section IV.B.1.a. (Significant Changes – Transfer Surface Adjustability), this is a new provision added to the final rule in conjunction with the new requirement of a...
-
223.1 General
In licensed medical care facilities and licensed long-term care facilities where the period of stay exceeds twenty-four hours, patient or resident sleeping rooms shall be provided in accordance...
-
2. Standing Supports
received two comments, one of which addressed standing supports on mammography equipment (discussed above in Section IV.D.1 (Significant Changes – Standing Supports)) and one commenter (medical...
-
M303.2.4.1 Breast Platforms
Wheelchair spaces beneath breast platforms shall comply with M303.2.4.1.
-
M303.2.4.1.1 Depth
Wheelchair spaces shall include knee and toe clearance 25 inches (635 mm) deep minimum and 28 inches (710 mm) deep maximum.
-
M303.2.4.1.2 Height
Wheelchair spaces shall include toe clearance 9 inches (230 mm) high minimum above the floor measured to a depth of 6 inches (150 mm) maximum from the toe end of the wheelchair...
-
11B-223.2 Hospitals, rehabilitation facilities, psychiatric facilities and detoxification facilities
Hospitals, rehabilitation facilities, psychiatric facilities and detoxification facilities shall comply with Section 11B-223.2. All public use and common use areas shall be...
-
a. Knee and Toe Clearance
The proposed rule recommended a knee and toe clearance depth for breast platforms of 25 inches. There were no comments received on this requirement. The MDE Advisory Committee...
-
5.8.2.4 Unobstructed Floor Space Recommendation
5.8.2.4 Unobstructed Floor Space Recommendation The Committee recommends the unobstructed floor space in front of the base support be a minimum of 17 inches deep. Rationale for...