At the dwelling unit side of the primary entry doors, secondary exterior doors, and required exit doors maneuvering clearances shall be 44 inches (1118 mm) minimum in length measured...
Search Results "Tape Measure"
Commonly Searched Documents
-
11B-809.8.3 Door maneuvering clearance.
-
11B-705.1.2.2.2.1 One entrance/exit point
Where the turning space has one entrance/exit point other than the sloped ramp segments, detectable warnings shall be 36 inches (914 mm) deep, as measured perpendicular to the curb, and...
-
11B-705.1.1.2 Dome spacing
detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch (16.5 mm) minimum, measured...
-
2. Accommodation in testing
that tests be given to people who have impaired sensory, speaking or manual skills in a format and manner that does not require use of the impaired skill, unless the test is designed to measure...
-
TERMS OF SETTLEMENT
. § 35.151) on Election Day, whether such compliance is achieved through permanent architectural measures or through the use of temporary measures such as those provided for in Paragraph...
- Better Living Classic Soap and Shower Dispenser 4
- Better Living AVIVA Soap and Shower Dispenser 2
- Better Living Classic Soap and Shower Dispenser 2
- Better Living Signature Soap and Shower Dispenser 2
- SafePath SafeShower™ Ramp Transitions
-
Character Spacing: ADA Standard Section 703.2.7
Character spacing shall be measured between the two closest points of adjacent raised characters within a message, excluding word spaces....
-
Height: ADA Standard Section 505.4
Section 505.4 covers the current ADA Standards for the height of the top of the gripping surface of handrails.
-
Overlap: ADA Standard Section 604.3.2
Section 604.3.2 covers the current ADA Standards for overlapping clearances in the water closet clear floor space.
-
Dispensers: ADA Standard Section 604.7
Section 604.7 covers the current ADA Standards for toilet paper dispensers.
-
11B-809.9.2 Clear width
Kitchens shall have a minimum clear width measured between any cabinet, work surface or the face of any appliance (excluding handles and controls) and the opposing cabinet, work surface,...
-
11B-703.2.7 Character spacing
Character spacing shall be measured between the two closest points of adjacent raised characters within a message, excluding word spaces....
-
11B-505.4 Height
A maximum height of 28 inches (710 mm) measured to the top of the gripping surface from the ramp surface or stair nosing is recommended for handrails designed for children....
- Just Manufacturing Automatic Soap Dispenser
- Seton Parking Signs - Van Accessible with ISA
- Seton Parking Signs - Blue Reserved Parking with ISA
- Inclusion Solutions Blue Parking Stop
-
Wheelbase Definition
Wheelbase Definition For the purpose of this analysis, wheelbase is defined as the distance from the center of the primary drive wheel to the center of the caster measured parallel to...
-
11B-502.6 Identification
Signs shall be 60 inches (1524 mm) minimum above the finish floor or ground surface measured to the bottom of the sign. [2010 ADAS] 502.6 Identification. ...
-
11B-502.6 Identification
Signs shall be 60 inches (1524 mm) minimum above the finish floor or ground surface measured to the bottom of the sign. [2010 ADAS] 502.6 Identification. ...