The product should comply with the following provisions ADAAG section 4.27 Controls and Operating Mechanisms ADAAG section 4.26 Handrails, Grab Bars Usable from a wheelchair...
Search Results "Wheelchair Space (Medical Diagnostic Equipment)"
-
PHYSICAL PROVISIONS
-
Car Controls [4.10.12]
Alignment for a side reach is often difficult at panels on the front of cars due to the limited maneuvering space; consider a maximum height of 48 inches for panels on the front of cars....
-
Dimensions for Adults and Children [§102]
The ADA Standards do not require provision of additional accessible elements in order to separately accommodate both children and adults, although doing so may be advisable in mixed use spaces...
-
11B-206.3 Location
An accessible route shall not pass through kitchens, storage rooms, restrooms, closets or other spaces used for similar purposes, except as permitted by Chapter 10. U.S....
-
11B-206.3 Location
An accessible route shall not pass through kitchens, storage rooms, restrooms, closets or other spaces used for similar purposes, except as permitted by Chapter 10. U.S....
-
1009.7.2 Separation
Exception: The fire-resistance rating and opening protectives are not required in the exterior wall where the building is equipped throughout with an automatic sprinkler system installed...
-
1009.7.2 Separation
Exception: The fire-resistance rating and opening protectives are not required in the exterior wall where the building is equipped throughout with an automatic sprinkler system installed...
-
Mirrors: ADA Standard Section 603.3
Section 603.3 covers the current ADA Standards for mirrors in toilet and bathing rooms.
-
11B-603.3 Mirrors
In order for mirrors to be usable by people who are ambulatory and people who use wheelchairs, the top edge of mirrors should be 74 inches (1880 mm) minimum from the floor or ground. ◼...
-
11B-603.3 Mirrors
In order for mirrors to be usable by people who are ambulatory and people who use wheelchairs, the top edge of mirrors should be 74 inches (1880 mm) minimum from the floor or ground. ◼...
-
PUBLIC USE
[DSA-AC] Interior or exterior rooms, spaces or elements that are made available to the public. Public use may be provided at a building or facility that is privately or publicly owned....
-
PUBLIC USE
[DSA-AC] Interior or exterior rooms, spaces or elements that are made available to the public. Public use may be provided at a building or facility that is privately or publicly owned....
- OPENspace
-
§ 37.165(b)(2)
(2) The entity is not required to permit wheelchairs to ride in places other than designated securement locations in the vehicle, where such locations exist. * * * * *...
-
12185(c)(2)
(2) members selected from among individuals with disabilities, particularly individuals who use wheelchairs, who are potential riders of such buses; and...
-
§100.205(c)(2)
(2) All the doors designed to allow passage into and within all premises are sufficiently wide to allow passage by handicapped persons in wheelchairs; and...
-
§ 37.165(b)(2)
(2) The entity is not required to permit wheelchairs to ride in places other than designated securement locations in the vehicle, where such locations exist....
- Geberit Monolith Floor Mounted Toilet with Black Glass
-
III. STRUCTURAL MODIFICATIONS TO WHC BUILDINGS AND FACILITIES
Notwithstanding the foregoing, because of space limitations in Rooms 5C 7, 11, and 19, these rooms will not be fully compliant with the ADA Standards because a patient will be able to transfer...
-
11B-812.5.2 Accessible route to EV charger
An accessible route complying with Section 11B-402 shall be provided between the vehicle space and the EV charger which serves it....
-
11B-812.5.2 Accessible route to EV charger
An accessible route complying with Section 11B-402 shall be provided between the vehicle space and the EV charger which serves it....
-
11B-409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by Section 11B-409.4.1....
-
11B-809.9.5 Lower shelving
Lower shelving and/or drawer space shall be provided at a height of 48 inches (1219 mm) maximum above the finish floor....