Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by Section 11B-409.4.1....
Search Results "Head End Wall"
-
11B-409.3.2 Location
-
11B-409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by Section 11B-409.4.1....
-
Alternate Roll-In Type Shower Compartments: ADA Standard Section 608.5.3
Section 608.5.3 covers the current ADA Standards for controls in alternate roll-in type shower compartments.
-
11B-608.5.3 Alternate roll-in type shower compartments
and 27 inches (686 mm) maximum from the seat wall or shall be located on the back wall opposite the seat 15 inches (381 mm) maximum, left or right of the centerline of the seat....
-
11B-608.5.3 Alternate roll-in type shower compartments
and 27 inches (686 mm) maximum from the seat wall or shall be located on the back wall opposite the seat 15 inches (381 mm) maximum, left or right of the centerline of the seat....
-
Clear Floor or Ground Space: ADA Standard Section 903.2
Clear floor or ground space complying with 305 shall be provided and shall be positioned at the end of the bench seat and parallel to the short axis of the bench....
-
1009.7.2 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
11B-608.5.2 Standard roll-in type shower compartments
) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor...
-
11B-608.5.2 Standard roll-in type shower compartments
) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor...
-
1009.7.2 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
- Neo-Metro Commercial Curved Front, Wall Mounted System M2 Basin 8980 Series
-
Size: ADA Standard Section 604.8.1.1
Section 604.8.1.1 covers the current ADA Standards for the size of wheelchair accessible compartments.
-
Grab Bars: ADA Standard Section 604.5
Section 604.5 covers the current ADA Standards for grab bars that are used for water closets.
-
11B-903.2 Clear floor or ground space
Clear floor or ground space complying with Section 11B-305 shall be provided and shall be positioned at the end of the bench seat and parallel to the short axis of the bench....
-
11B-903.2 Clear floor or ground space
Clear floor or ground space complying with Section 11B-305 shall be provided and shall be positioned at the end of the bench seat and parallel to the short axis of the bench....
-
Size: ADA Standard Section 604.3.1
Section 604.3.1 covers the current ADA Standards for the size of the water closet clearance.
-
11B-809.10.7.3 Reinforcement for grab bars
Where water closets are placed adjacent to a side wall, reinforcement shall be installed on both sides or one side and the back....
-
11B-809.10.7.3 Reinforcement for grab bars
Where water closets are placed adjacent to a side wall, reinforcement shall be installed on both sides or one side and the back....
- EVSE AutoWind EV (Electric Vehicle) Charger Single Pole, Dual Pole or Wall Mount
- Sloan WETS 2050.1201-1.28 Solar-Powered HET Flushometer and HET Wall Hung Water Closet
-
11B-604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
-
11B-604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
-
Location: ADA Standard Section 604.9.1
Section 604.9.1 covers the current ADA Standards for the mounting location of children's use water closets.