Search Results "Head End Wall"
Commonly Searched Documents
- Murdock Manufacturing Floor Mount, Wall Outlet Toilet
- H-7101-B Wall Sconce by Hi-Lite
- H-12252-B Wall Sconce by Hi-Lite
- Bradley Imperial Wall-Mount Lavatory TL-18
- H-702-B Wall Sconce by Hi-Lite
- H-7102-B Wall Sconce by Hi-Lite
- H-701-B Wall Sconce by Hi-Lite
-
Size: ADA Standard Section 604.8.1.1
Section 604.8.1.1 covers the current ADA Standards for the size of wheelchair accessible compartments.
-
11B-809.10.7.3 Reinforcement for grab bars
Where water closets are placed adjacent to a side wall, reinforcement shall be installed on both sides or one side and the back....
-
Grab Bars: ADA Standard Section 604.5
Section 604.5 covers the current ADA Standards for grab bars that are used for water closets.
-
Alternative Designs
The 24" high sides make it impossible to install the two grab bars on the back wall in the manner prescribed in ADAAG....
-
11B-409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by Section 11B-409.4.1....
-
Size: ADA Standard Section 604.3.1
Section 604.3.1 covers the current ADA Standards for the size of the water closet clearance.
-
Clearances Around Gripping Surfaces
Guidelines specify the following clearances around grab bars to ensure sufficient space for a person to grasp the grab bar: 1½ inches absolute clearance between grab bars and the adjacent wall...
-
Location: ADA Standard Section 604.9.1
Section 604.9.1 covers the current ADA Standards for the mounting location of children's use water closets.
-
11B-604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
- Neo-Metro Commercial Curved Front, Wall Mounted System M2 Basin 8980 Series
-
Clear Floor or Ground Space: ADA Standard Section 903.2
Clear floor or ground space complying with 305 shall be provided and shall be positioned at the end of the bench seat and parallel to the short axis of the bench....
-
4.9.4 HANDRAILS
(3) The clear space between handrails and wall shall be 1-1/2 in (38 mm)....
-
4.16.6 Dispensers
that nursing staff at Memorial Hospital of Martinsville and Henry County (Martinsville, VA), felt that 24" would provide sufficient space for staff and still permit a patient to reach a wall-mounted...
- EVSE AutoWind EV (Electric Vehicle) Charger Single Pole, Dual Pole or Wall Mount
-
11B-903.2 Clear floor or ground space
Clear floor or ground space complying with Section 11B-305 shall be provided and shall be positioned at the end of the bench seat and parallel to the short axis of the bench....
- Sloan WETS 2050.1201-1.28 Solar-Powered HET Flushometer and HET Wall Hung Water Closet
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall....