The rear edge of a rectangular seat shall be 2 1/2 inches (64 mm) maximum and the front edge 15 inches (380 mm) minimum and 16 inches (405 mm) maximum from the seat wall....
Search Results "Wing Wall"
-
610.3.1 Rectangular Seats
-
E2-1. Pedestrian Routes
[ADA Stds. 4.4] Note: These objects may be wall mounted or free standing....
-
Hallways
ADA Requirements Wall-mounted objects located between 27 inches and 80 inches above the floor may not protrude or stick out from the wall more than 4 inches....
-
704.3 Buildings on the same property and buildings containing courts
For the purposes of determining the required wall and opening protection and roof-covering requirements, buildings on the same property and court walls of buildings over one story in height...
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
-
1134A.7, Item 2
Reinforced walls for grab bars. ...
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
-
1134A.7, Item 2
Reinforced walls for grab bars....
-
11B-604.3.1 Size
Clearance around a water closet shall be 60 inches (1524 mm) minimum measured perpendicular from the side wall and 56 inches (1422 mm) minimum measured perpendicular from the rear wall....
-
11B-809.10.6.1 Size
closet shall be permitted to project 12 inches (305 mm) maximum into the opening provided that 36 inches (914 mm) minimum clear space is maintained between the water closet and the shower wall...
-
11B-610.3.1 Rectangular seats
The rear edge of a rectangular seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (381 mm) minimum and 16 inches (406 mm) maximum from the seat wall....
-
610.3.1 Rectangular Seats
The rear edge of a rectangular seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (380 mm) minimum and 16 inches (405 mm) maximum from the seat wall....
-
Controls [4.21.5]
Controls [4.21.5] Controls and shower units can be located on any wall but where a folding seat is provided they must be located to be within reach of a person on the seat....
-
11B-604.7.2 Disposal units
Sanitary napkin disposal units, if provided, shall comply with Section 11B-309.4 and shall be wall mounted and located on the sidewall between the rear wall of the toilet and the toilet...
-
§ 38.107(a)(3)
(3) A grab bar at least 24 inches long shall be mounted behind the water closet, and a horizontal grab bar at least 40 inches long shall be mounted on at least one side wall, with one end...
-
§ 38.123(a)(3)
(3) A grab bar at least 24 inches long shall be mounted behind the water closet, and a horizontal grab bar at least 40 inches long shall be mounted on at least one side wall, with one end...
-
11B-608.5.1 Transfer type shower compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm...
-
608.5.1 Transfer Type Shower Compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm...
-
704.11.1 Parapet construction
Parapets shall have the same fire-resistance rating as that required for the supporting wall, and on any side adjacent to a roof surface, shall have noncombustible faces for the uppermost...
-
604.2 Location
The water closet shall be positioned with a wall or partition to the rear and to one side....
-
30.1 Q. Would it be acceptable to use removable base cabinets beneath a wall-hung lavatory where a parallel approach is not possible?
A. Yes. The space under and around the cabinet should be finished prior to installation. For example, the tile or other floor finish must extend under the removable base cabinet.
-
Willoughby Industries ETW-1490-FM-HC Floor Mount Wall Outlet Rear Mounted ADA Blow Out Type Flush Toilet
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Section 307 Protruding Objects
This dryer protrudes more than 4" from the wall and is greater than 27" above the finish floor. Isn't this a violation of Section 307 Protruding Objects?...
-
11B-804.2.1 Pass through kitchen
In pass through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing...