Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall. Figure 409.4.6.2 Location of Private Residence Elevator Control Panel...
Search Results "Wing Wall"
-
409.4.6.2 Location
-
H23
Is the door to the toilet stall located diagonally opposite, not directly in front of, the toilet or on the opposite side wall from the wall with the long grab bar?...
-
610.3.2 L-Shaped Seats
The rear edge of an L-shaped seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (380 mm) minimum and 16 inches (405 mm) maximum from the seat wall....
-
11B-409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall. FIGURE 11B-409.4.6.2 LOCATION OF PRIVATE RESIDENCE ELEVATOR CONTROL PANEL...
-
409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall. Figure 409.4.6.2 Location of Private Residence Elevator Control Panel...
-
608.5.2 Standard Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be installed on the back wall adjacent to the seat wall and shall be located 27 inches (685 mm) maximum from...
-
608.5.3 Alternate Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...
-
608.5.2 Standard Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be installed on the back wall adjacent to the seat wall and shall be located 27 inches (685 mm) maximum from...
-
608.5.3 Alternate Roll-In Type Shower Compartments
Where a seat is provided, the controls, faucets, and shower spray unit shall be located on the side wall adjacent to the seat 27 inches (685 mm) maximum from the side wall behind the seat...
-
1009.7.2 Separation
Exterior walls separating the exterior area of assisted rescue from the interior of the building shall have a minimum fire-resistance rating of 1 hour, rated for exposure to fire from the...
-
604.5 Grab Bars
Grab bars shall be provided on the side wall closest to the water closet and on the rear wall. EXCEPTIONS: 1....
-
604.8.1.1 Size
Wheelchair accessible compartments shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and...
-
604.8.1.1 Size
Wheelchair accessible compartments shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and...
-
604.8.1.1 Size
Wheelchair accessible compartments shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and...
-
11B-604.8.1.1 Size
Wheelchair accessible compartments shall be 60 inches (1524 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1422 mm) deep minimum for wall hung water closets and...
-
Back Support
Commenters requested clarification as to whether walls can be used to provide back support where the seat is attached to walls....
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall....
-
604.3.1 Size
Clearance around a water closet shall be 60 inches (1525 mm) minimum measured perpendicular from the side wall and 56 inches (1420 mm) minimum measured perpendicular from the rear wall....
-
Clarification on Standard Roll-In Shower Compliance
Since there’s no maximum length for a side wall in a standard roll-in shower, do you think a pull-down grab bar would still be allowed?...
-
Clearance: ADA Standard Section 804.2
Clearances are measured from the furthest projecting face of all opposing base cabinets, counter tops, appliances, or walls, excluding hardware....
-
604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
-
604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
-
604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....
-
11B-604.9.1 Location
The water closet shall be located with a wall or partition to the rear and to one side....