Ramp landing length specified by Section 11B-405.7.3 shall be permitted to be 48 inches (1219 mm) long minimum....
Search Results "Segment Length"
Commonly Searched Documents
-
11B-1007.2 Accessible routes
-
Part 1. Typical Issues for Voters Who Use Wheelchairs, Scooters or Other Mobility Aids
Ramps must also have edge protection to stop wheelchairs from falling off the sides, and level landings at the top and bottom of each segment and where a ramp changes direction....
-
ADA Tolerances - Additional Resources
1bf95c2cb091 TCNA Handbook, Tile Council of North America, has section on Accessibility https://www.tcnatile.com/products-and-services/publications.html Construction Tolerances for Segmental...
-
607.2 Clearance
Clearance in front of bathtubs shall extend the length of the bathtub and shall be 30 inches (760 mm) wide minimum....
-
406.4 Landings
The landing clear length shall be 36 inches (915 mm) minimum. The landing clear width shall be at least as wide as the curb ramp, excluding flared sides, leading to the landing....
-
11B-403.7 Continuous gradient
All walks with continuous gradients shall have resting areas, 60 inches (1524 mm) in length, at intervals of 400 feet (121,920 mm) maximum....
-
R304.2.2 Running Slope
The running slope of the curb ramp shall be 5 percent minimum and 8.3 percent maximum but shall not require the ramp length to exceed 4.5 m (15.0 ft)....
-
810.2.2 Dimensions--Modification to 810.2.2 of Appendix D to 36 CFR Part 1191
810.2.2 Dimensions--Modification to 810.2.2 of Appendix D to 36 CFR Part 1191 Bus boarding and alighting areas shall provide a clear length of 96 inches (2440 mm), measured perpendicular...
-
4.1.3 Adjustable Height Chairs with and without Footplates
keeping their legs properly positioned.AA For those chairs that transform into examination tables, reducing the distance between the floor and seat height may also restrict the overall length...
-
Gangway Slope and Rise Exceptions
Gangway Slope and Rise Exceptions Gangways must be designed to provide for a maximum 1:12 (8.33%) slope but are not required to be longer than 30 feet in length....
-
Technical Memorandum TM 2013-14 Dining Surfaces
Length Clear floor space complying with TAS 305 for a forward approach is required for an accessible dining surface based on TAS 902.2....
-
4. Wheelchair seat depth
Individual wheelchair seat depths are generally about 2 in. less than buttock-popliteal length in most case – this is a rough guideline and is quite similar to deciding seat depths for ambulatory...
-
11B-405.7.5 Doorways
Where a door swings onto a ramp landing width, additional ramp landing length as specified may be necessary to accommodate a clear level area for the wheelchair user to clear the door swing...
-
11B-809.10.7.3 Reinforcement for grab bars
The backing shall 40 (sic) inches (1016 mm) minimum in length....
-
1005.1 Accessible Routes
Where the total length of the gangway or series of gangways serving as part of a required accessible route is 30 feet (9145 mm) minimum, gangways shall not be required to comply with 405.2...
-
1005.1 Accessible Routes
Where the total length of the gangway or series of gangways serving as part of a required accessible route is 30 feet (9145 mm) minimum, gangways shall not be required to comply with 405.2...
-
Gripping Surface Cross Section and Clearances M301, M302, and M305.2
Interruptions along the bottom of the transfer support gripping surface will not obstruct more than 20% of its length per ADA and ABA 2004 Guidelines Section 505.6....
-
§ 36.303(c)(1)(ii)
(ii) The type of auxiliary aid or service necessary to ensure effective communication will vary in accordance with the method of communication used by the individual, the nature, length,...
-
1005.1 Accessible Routes
Where the total length of the gangway or series of gangways serving as part of a required accessible route is 30 feet (9145 mm) minimum, gangways shall not be required to comply with 405.2...
-
4.8.4 LANDINGS
(2) The landing length shall be a minimum of 60 in (1525 mm) clear....
-
§ 35.160(b)(2)
(2) The type of auxiliary aid or service necessary to ensure effective communication will vary in accordance with the method of communication used by the individual; the nature, length,...
-
§ 38.29(e)
(e) For vehicles in excess of 22 feet in length with front-door lifts or ramps, vertical stanchions immediately behind the driver shall either terminate at the lower edge of the aisle-facing...
-
11B-1005.1 Accessible routes
Where the total length of the gangway or series of gangways serving as part of a required accessible route is 30 feet (9144 mm) minimum, gangways shall not be required to comply with Section...
-
11B-809.10.7.2 Location
The centerline of the water closet shall be 17 inches (432 mm) minimum to 18 inches (457 mm) maximum from a wall or partition that is 54 inches (1372 mm) minimum in length....