2.4.1 Based on the methods for measuring compliance, define what remedial actions are acceptable when construction elements exceed tolerances....
Search Results "Tolerance"
-
2.4.1
-
3 - Best practices for pre - construction meetings
Unusual or particularly tight tolerances can be discussed, questions asked, construction techniques suggested, measurement methods outlined, and how compliance will be checked can all be...
-
F104.1.1 Construction and Manufacturing Tolerances
Advisory F104.1.1 Construction and Manufacturing Tolerances....
-
4 - Best practices for construction observation
4 - Best practices for construction observation Construction observation is the final step in building an accessible element to meet design and regulatory requirements. Even...
-
Suggested accessibility guidelines for exterior concrete surfaces
for Tolerances for Concrete Construction and materials and Commentary....
-
1.1.1 Measurement tools
For measuring device accuracy, the instrument and technique for measurement should provide for an accuracy of at least one - third the required tolerance....
-
1.1.8 Alternate measurement tools
Walks may be measured with instruments other than a digital inclinometer if they provide the data required for evaluation of tolerances as given in Sections 1.2.1, 1.2.2, and 1.2.3....
-
1.2.1 Walks and other non - ramp surfaces
When overall running slope for walks is measured according to Section 1.1.3 a recommended tolerance for running slope is +1%....
-
1.2.2
1.2.2 When flatness of running slope for an accessible surface other than a ramp is measured according to Section 1.1.5 no more than 20% (rounded to the nearest whole number) of the...
-
1.2.3 Landings
Both measurements of ramp landings as described in Section 1.1.15 should not exceed a plus tolerance of 0.5%....
-
1.2.4
1.2.4 When local horizontal discontinuities and vertical alignments are measured according to Section 1.1.9 a recommended tolerance is ±1/8 in. (3 mm)....
-
1.2.5 Ramps
When overall running slope and cross slope for accessible ramps are measured according to Sections 1.1.11 a recommended tolerance for these slopes is +0.5%....
-
1.2.6
1.2.6 When local variations (flatness) in running slope of ramps are measured according to 1.1.13 at least 80% (rounded to the nearest whole number) of the measurements should not...
-
1.2.7
1.2.7 When local variations (flatness) for cross slope of ramps are measured according to 1.1.14 at least 80% (rounded to the nearest whole number) should not exceed a 2% slope. The...
-
1.2.8 Exterior stairs, cast - in - place
When cast - in - place exterior stairs are measured according to Section 1.1.17 the requirements of the local building code shall govern tolerances....
-
3.2 Dimensional Tolerances
All dimensions are subject to conventional building industry tolerances for field conditions....
-
3.2 DIMENSIONAL TOLERANCES
All dimensions are subject to conventional building industry tolerances for field conditions....
-
Metal measuring tapes
The National Institute of Standards and Technology publishes tolerances for metal tapes in its Handbook 44, Section 5.52....
-
Chapter M1 Application and Administration
-
104 Conventions
A commenter stated that the 2010 Standards restrict the application of construction tolerances only to those few requirements that are expressed as an absolute dimension....
-
M101.5 Dimensional Tolerances
Dimensions are subject to conventional industry tolerances for manufacturing processes, material properties, and field conditions. Question 5....
-
Dimensional Tolerances [3.2]
ADAAG recognizes conventional industry tolerances for field conditions. This applies to the field work, not the design work....