Search Results "Extended Floor Surface"
- Georgia-Pacific Compact Quad® Vertical Four Roll Coreless Tissue Dispenser 56747
- Midmark Ritter 222 Barrier-Free® Power Examination Table
- Mansfield Cascade Commercial Package Urinal and Flush Valve CP-410
- Greenfields Outdoor Fitness Two-Person Accessible Combo Butterfly and Reverse Fly GR2005-1-48E-W (2 Configurations)
- Georgia-Pacific Compact Quad® Vertical Four Roll Coreless Tissue Dispenser 56743
- Hill-Rom Likorall™ 242 S Overhead Lift
- BraunAbility Century 2 Wheelchair Lift for School Buses, Cutaway Buses, and Paratransit Vans
-
[F] 907.4.2.2 Height
The height of the manual fire alarm boxes shall be a minimum of 42 inches (1067 mm) and a maximum of 48 inches (1219 mm) measured vertically, from the floor level to the activating handle...
-
241 and 612 Saunas and Steam Rooms
Doors are not permitted to swing into the clear floor or ground space for the accessible bench....
-
TEST NO. 3 – UNUSUAL CHARACTERISTICS TEST
include sites located in a state or federally designated floodplain or coastal high-hazard areas and sites subject to other similar requirements of law or code that require the lowest floor...
-
11B-604.7 Dispensers
The outlet of the dispenser shall be below the grab bar, 19 inches (483 mm) minimum above the finish floor and shall not be located behind grab bars....
-
4.4 Equipment Barriers and Solutions
Low cost Involved / High cost Spaces between the equipment are too narrow Ask staff to move one of each type of equipment to the end of the aisle where there is extra floor...
-
407.12.3.2.2 Knee and Toe Space
Toe space shall be permitted to provide a clear height of 9 inches (230 mm) minimum above the floor and a clear depth of 6 inches (150 mm) maximum from the vertical reference plane toward...
-
11B-404.2.11 Vision lights
gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel located 43 inches (1092 mm) maximum above the finish floor...
-
11B-404.2.11 Vision lights
gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel located 43 inches (1092 mm) maximum above the finish floor...
-
1009.8 Two-way communication
A two-way communication system complying with Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is...
-
11B-608.5.2 Standard roll-in type shower compartments
the seat 16 inches (406 mm) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor...
-
Best Practice Recommendations for Layout Planning
If accessible restrooms are not on the same floor, increase break times between sessions....
-
1009.5.2 Transfer Space
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface....
-
403.5.1 Clear Width
Except as provided in 403.5.2 and 403.5.3, the clear width of walking surfaces shall be 36 inches (915 mm) minimum....
-
1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface....
-
R406.3 Unobstructed Side Reach
approach to an element and the side reach is unobstructed, the high side reach shall be 1220 mm (4.0 ft) maximum and the low side reach shall be 380 mm (1.25 ft) minimum above the finish surface...
-
Built-up Curb Ramps [4.7.6]
(The surface of access aisles cannot slope more than 2% in any direction)....