The accessible route must comply with ADAAG provisions for the location, width (minimum of 36 inches), passing space, head room, surface, slope (maximum of 1:12 or 8.33%), changes in level...
Search Results "Extended Floor Surface"
Commonly Searched Documents
-
Accessible Routes
-
Accessible Routes
Accessible route requirements in ADAAG address width (minimum of 36 inches), passing space, head room, surface, slope (maximum of 1:12 or 8.33%), changes in level, doors, egress, and areas...
-
703.7.1 Finish and Contrast
Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text...
-
Cashier counters
Museum Gift Shop (provide a temporary surface, such as a clipboard, and install a permanent counter within twenty-four months); ii. Spy City Café; and iii....
-
B. Measuring Clear Passage at Doors
The photo below shows that you measure horizontally from the face of the door in its 90 degree open position to the surface of the door stop on the frame opposite the hinge....
-
4. Parking and passenger loading zones
4.6 If provided at the site, designated accessible parking at the dwelling unit on request of residents with handicaps, on the same terms and with the full range of choices (e.g. surface...
-
703.7.1 Finish and Contrast
Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text...
-
11B-703.5.1 Finish and contrast
Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text...
-
11B-703.6.2 Finish and contrast
Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text...
-
11B-703.7.1 Finish and contrast
Additional factors affecting the ease with which the text can be distinguished from its background include shadows cast by lighting sources, surface glare, and the uniformity of the text...
-
Medical Diagnostic Equipment: ADA Standard Section 5.
Review the updated information on the revisions to the ADA Standards regarding medical diagnostic equipment.
-
Q1.) When a ramp has a maximum slope of 1:12 or 8.33%, is that considered a range of from 0% to 8.33% which would allow no slope greater than 8.33% or is that a simple maximum which would allow a tolerance above 8.33%? Similarly, is a cabinet countertop that can be no higher than 34” AFF a range of from 0” to 34” AFF with no additional height allowed, or is a tolerance allowed for variations in the floor surface or cabinet construction?
A1.) The consistent technical assistance on this question has been that both are subject to tolerances.
- Wingits Reversible L-shaped 26" x 22.5" Shower Seat
- Cybex Total Access Upright Bike
-
A. DEFINITIONS AND BACKGROUND
In order to be deemed accessible, a bed must (i) lower to a point no greater than 17-19 inches from the floor, and (ii) be capable of being locked or otherwise fixed into position so as...
-
Shower Compartments
inch maximum curb in transfer-type showers in alterations to existing facilities, where recessing the compartment to achieve a ½-inch curb will disturb the structural reinforcement of the floor...
-
Display Screens
suggested that we change the requirement for display screens such that they must not only be visible, but also readable, from a point located 40 inches (1015 mm) above the center of the clear floor...
-
4.1.3(5)*
For example, floors above or below the accessible ground floor must meet the requirements of this section except for elevator service....
-
11B-608.3 Grab bars
Where multiple grab bars are used, required horizontal grab bars shall be installed at the same height above the finish floor....
-
Before January 26, 1992
One program access solution in this case might be to make a video of the second floor exhibits for people to watch on the first floor....
-
604.8.1.1 Size
shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and 59 inches (1500 mm) deep minimum for floor...
-
SAFE HARBOR
EXAMPLE In 2005 a museum renovated restrooms and installed paper towel dispensers at 54 inches from the floor in order to be in compliance with the 1991 ADA Standards....
-
604.8.1.1 Size
shall be 60 inches (1525 mm) wide minimum measured perpendicular to the side wall, and 56 inches (1420 mm) deep minimum for wall hung water closets and 59 inches (1500 mm) deep minimum for floor...
-
Scenario 8 – Accessibility
Ayana, who is unable to walk upstairs due to her disability, is dismayed when she discovers that the art studio is on the second floor; she had planned to take an art class the following...