Where stationary ICT provides one or more display screens, at least one of each type of display screen shall be visible from a point located 40 inches (1015 mm) above the floor space where...
Search Results "Extended Floor Surface"
-
408.1 General
-
Automatic Door
The switch that begins the automatic cycle may be a photoelectric device, floor mat, or manual switch (see power-assisted door)....
-
306.3.4 Clearance Reduction
Between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
7.3 CHECK-OUT AISLES
Clear aisle width shall comply with 4.2.1 and maximum adjoining counter height shall not exceed 36 in (915 mm) above the floor....
-
Laser scanners
These types of instruments could be used to measure floor flatness and level but they are very expensive, require training, and give accuracies in excess of what is needed for accessible...
-
11B-203.11 Water slides
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
11B-203.11 Water slides
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
604.8.3 Coat Hooks and Shelves
Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor....
-
603.4 Coat Hooks and Shelves
Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor....
-
306.3.4 Clearance Reduction
Between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
- Palmer Fixture iSTORM2 High Speed Hand Dryer
-
Significant alternatives which minimize any significant economic impacts on small entities
analyzes the following four requirements in the proposed guidelines that will have more than minimal impacts on state and local transportation departments: Detectable warning surfaces...
-
4.3.2 Seat Height
4.3.2 Seat Height Seat height is an important dimension for establishing the height of built-in seating, toilet heights, tub heights, shower seat heights and other transfer related surfaces...
-
Characteristics of Study Participants
of community mobility is related to the “accessibility” of outdoor surfaces....
-
References
Standard specification for impact attenuation of surface systems under and around playground equipment. ASTM F1292‒99/04, 15.07. ...
-
Alterations [4.1.6(1)(f) & (k)]
Thus, the exception from the requirement for an elevator in buildings with less than 3 stories or with less than 3,000 square feet per floor applies to altered facilities as well, including...
-
SHOPPING CENTER (OR SHOPPING MALL)
A shopping center may include a series of buildings on a common site, connected by a common pedestrian access route on, above or below the ground floor, that is either under common ownership...
-
11B-307.2 Protrusion limits
Objects with leading edges more than 27 inches (686 mm) and not more than 80 inches (2032 mm) above the finish floor or ground shall protrude 4 inches (102 mm) maximum horizontally into...
-
Protrusion Limits: ADA Standard Section 307.2
Section 307.2 covers the current ADA Standards for protrusion limits.
-
Path of Travel
(2) An accessible path of travel may consist of walks and sidewalks, curb ramps and other interior or exterior pedestrian ramps; clear floor paths through lobbies, corridors, rooms,...
-
11B-307.2 Protrusion limits
Objects with leading edges more than 27 inches (686 mm) and not more than 80 inches (2032 mm) above the finish floor or ground shall protrude 4 inches (102 mm) maximum horizontally into...
-
1009.6.3 Size
Exception: The enforcing agency may reduce the size of each required area of refuge to accommodate one wheelchair space that is not less than 30 inches by 52 inches (762 mm by 1320 mm) on floors...
-
1009.6.3 Size
Exception: The enforcing agency may reduce the size of each required area of refuge to accommodate one wheelchair space that is not less than 30 inches by 52 inches (762 mm by 1320 mm) on floors...
-
Designations: ADA Standard Section 216.2
Section 216.2 covers scoping requirements in the current ADA Standards for sign designations.