Where drinking fountains are provided on an exterior site, on a floor, or within a secured area they shall be provided in accordance with F211....
Search Results "Extended Floor Surface"
-
F211.1 General
-
(5) Reinforced walls for grab bars
The only change made to these guidelines has been to subject powder rooms to the reinforced wall requirement when the powder room is the only toilet facility on the accessible floor of a...
-
I. Security
Is the security latch or bolt on the hall door mounted no higher than 48" above the floor so it is within the reach of persons who use wheelchairs and is it operable with one hand, without...
-
D6
If an entry has a vestibule, is there a 30-inch by 48-inch clear floor space inside the vestibule where a wheelchair or scooter user can be outside the swing of a hinged door?...
-
J6
Is the bottom of the apron of the fountain 27 inches above the floor so that it provides the space needed for a person who uses a wheelchair to pull up under it but is not a hazard to people...
-
Side Reach [§308.3]
The maximum reach depth for this range is 10” measured from the available clear floor space....
-
§ 38.93(d)(2) Exception
New vehicles operating in existing stations may have a floor height within plus or minus 11/2 inches of the platform height....
-
11B-203.10 Raised refereeing, judging, and scoring areas
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
11B-233.3.1.2.1 Elevator buildings
Residential dwelling units on floors served by an elevator shall be adaptable....
-
11B-203.10 Raised refereeing, judging, and scoring areas
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
217.4.1 Bank Requirement
EXCEPTION: TTYs shall not be required at banks of telephones located within 200 feet (61 m) of, and on the same floor as, a bank containing a public TTY....
-
233 Residential Facilities
(1) In sleeping rooms with more than 25 beds covered by this section, a minimum of 5% of the beds shall have clear floor space complying with section 806.2.3 of the 2010 Standards....
- Panda S.10 All Aluminum Lift & Slide System
-
1009.5.2 Transfer Space
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface....
-
R406.3 Unobstructed Side Reach
approach to an element and the side reach is unobstructed, the high side reach shall be 1220 mm (4.0 ft) maximum and the low side reach shall be 380 mm (1.25 ft) minimum above the finish surface...
-
Built-up Curb Ramps [4.7.6]
(The surface of access aisles cannot slope more than 2% in any direction)....
-
Wheelchair Work Measurement Method
Wheelchair work per meter values for straight and turning were determined for all test course surfaces except sand, under dry conditions using the Wheelchair Work Measurement Method in accordance...
-
Fixed tactile maps
Placement on a horizontal or near horizontal surface provides the map reader with a real world orientation....
-
6.9 Tread Obstacles
Where the surface is paved or is elevated above the natural ground, obstacles shall not exceed 1/2 inch (13 mm) in height measured vertically to the highest point....
-
Original research for ANSI A117.1 (1957 - 1961)
Buildings and Facilities Accessible to, and Usable by, the Physically Handicapped, ramps were assessed for flatness based on measuring 18 - inch increments on both edges of the ramped surface...
-
11B-704.5 TTY shelf
The telephone handset shall be capable of being placed flush on the surface of the shelf....
-
1005.2.1 Height
At least 25 percent of the railings, guards, or handrails shall be 34 inches (865 mm) maximum above the ground or deck surface....
-
403.5.1 Clear Width
Except as provided in 403.5.2 and 403.5.3, the clear width of walking surfaces shall be 36 inches (915 mm) minimum....