Where signs identify a station or its entrance, at least one sign at each entrance shall comply with 703.2 and shall be placed in uniform locations to the maximum extent practicable....
Search Results "High Speed Rail"
Commonly Searched Documents
-
810.6.1 Entrances
-
705.2 Platform Edges
Detectable warning surfaces at platform boarding edges shall be 24 inches (610 mm) wide and shall extend the full length of the public use areas of the platform.
-
810.6.1 Entrances
Where signs identify a station or its entrance, at least one sign at each entrance shall comply with 703.2 and shall be placed in uniform locations to the maximum extent practicable....
-
T703 International Symbol of Accessibility
[See subsections ...]
-
T209 Fare Collection Devices
[See subsections ...]
-
T213 Seats
[See subsections ...]
-
705.2 Platform Edges
705.2 Platform Edges. Detectable warning surfaces at platform boarding edges shall be 24 inches (610 mm) wide and shall extend the full length of the public use areas of the platform.
-
16. In § 38.111
§ 38.111 [Amended] 16. In § 38.111,
-
10.3.1(12)(a)
(a) If an interior public pay telephone is provided in a transit facility (as defined by the Department of Transportation) at least one interior public text telephone shall be...
-
10.3.1(17)
(17) Where provided, elevators shall be glazed or have transparent panels to allow an unobstructed view both in to and out of the car. Elevators shall comply with 4.10. EXCEPTION:...
-
10.3.3(1)
(1) For the purpose of complying with 4.1.6(2) Alterations to an Area Containing a Primary Function, an area of primary function shall be as defined by applicable provisions of 49...
-
Additional Technical Criteria Considered for Handrails on Ramps
M303.3.3.5 would require handrails to be provided on each side of the ramp when the vertical rise of the ramp exceeds 6 inches. This is consistent with the 2004 ADA and ABA...
-
§ 38.125(c)(6) Attachment
(6) Attachment—
-
11B-705.1.2.1 Platform edges
11B-705.1.2.1 Platform edges. Detectable warning surfaces at platform boarding edges shall be 24 inches (610 mm) wide and shall extend the full length of the public use areas of the...
-
§ 38.105 Priority seating signs
[See subsections ...]
-
11B-247.1.2.1 Platform edges
Platform boarding edges shall have detectable warnings complying with Sections 11B-705.1.1 and 11B-705.1.2.1.
-
§ 38.117 Floors, steps and thresholds
[See subsections ...]
-
§ 38.127(b)
(b) Each accessible compartment shall contain a restroom complying with §38.123(a) which can be entered directly from such compartment.
-
§ 38.125(b)(2)(i) Requirements
(i) Requirements. The controls shall be interlocked with the car brakes, propulsion system, or door, or shall provide other appropriate mechanisms or systems, to ensure that the car...
-
§ 38.83(b)(7) Platform gaps
(7) Platform gaps. Any openings between the lift platform surface and the raised barriers shall not exceed 5/8 inch wide. When the lift is at vehicle floor height with the inner...
-
§ 38.105(a)
(a) Each car shall contain sign(s) which indicate that certain seats are priority seats for persons with disabilities and that other passengers should make such seats available to...
-
11B-810.6.1 Entrances
Where signs identify a station or its entrance, at least one sign at each entrance shall comply with Section 11B-703.2 _|Signs; Raised Characters|_ and shall be placed in uniform...
-
§ 38.125(c)(1) Design load
(1) Design load. Ramps or bridge plates 30 inches or longer shall support a load of 600 pounds, placed at the centroid of the ramp or bridge plate distributed over an area of 26...
-
§ 38.125(c)(7) Stowage
(7) Stowage. A compartment, securement system, or other appropriate method shall be provided to ensure that stowed ramps or bridge plates, including portable ramps or bridge plates...