Individual self-service storage spaces shall be dispersed throughout the various classes of spaces provided....
Search Results "Lavatory Clear Floor Space"
-
11B-225.3.1 Dispersion
-
11B-225.3.1 Dispersion
Individual self-service storage spaces shall be dispersed throughout the various classes of spaces provided....
-
11B-208.2.3 Residential facilities
Where at least one parking space is provided for each dwelling unit, at least one accessible space is required for each mobility accessible unit provided (11B-208.2.3.1) and those spaces...
-
11B-809.10.5.2 Reinforcement for grab bars
Where bathtubs are installed without surrounding walls reinforcement shall be provided for floor-mounted grab bars. 2....
-
11B-809.10.5.2 Reinforcement for grab bars
Where bathtubs are installed without surrounding walls reinforcement shall be provided for floor-mounted grab bars. 2....
-
Lift Compatibility (M301.4 and M302.4)
ANSI/AAMI HE 75 recommends that the “base of the device needs to have space underneath or along both sides (if the equipment is narrow) to accommodate the legs of portable mechanical lift...
-
Section 2. Accessible route
"Accessible route" means a continuous unobstructed path connecting accessible elements and spaces in a building or within a site that can be negotiated by a person with a severe disability...
-
§100.201 Accessible route
Accessible route means a continuous unobstructed path connecting accessible elements and spaces in a building or within a site that can be negotiated by a person with a severe disability...
-
11B-604.7 Dispensers and disposal units
Combination accessory units are not permitted to encroach into the space required by Section 11B-609.3. [2010 ADA Standards] 604.7 Dispensers....
-
For People with Disabilities, Which Circulation Paths Are Usable, Available, and Closest?
The requirements include but are not limited to the type, size, spacing, and color of letters for visual characters and the type, size, location, character height, stroke width, and line...
-
Height: ADA Standard Section 407.4.6.4.1
Section 407.4.6.4.1 covers the current ADA Standards for the height of the emergency controls in elevator cars.
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor....
-
11B-407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (889 mm) minimum above the finish floor....
-
1117B.5.7
Where permanent identification signage is provided for rooms and spaces they shall be located on the approach side of the door as one enters the room or space....
- LaCantina Multi-slide Thermally Controlled Aluminum Sliding Door System
-
1017.1 General
The technical requirements address the surface of the trails, passing spaces, and resting intervals (1017.2); the clear tread width of trails (1017.3); passing spaces (1017.4); tread obstacles...
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
-
11B-407.2.1.4 Location
A destination-oriented elevator system provides lobby controls enabling passengers to select floor stops, lobby indicators designating which elevator to use, and a car indicator designating...
-
11B-407.2.1.4 Location
A destination-oriented elevator system provides lobby controls enabling passengers to select floor stops, lobby indicators designating which elevator to use, and a car indicator designating...
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
- Department of Homeland Security
-
UDI
Maneuvering trials were recorded using overhead video cameras while participants completed standardized movements in simulated environments built with plywood floors and wood framed dividers...