At least two handrails complying with 505 shall be provided on the sloped entry....
Search Results "Cross Slope"
Commonly Searched Documents
- 
    
  
  1009.3.3 Handrails
  
- 
    
  
  1.1.1
  For example, the 1:12 slope stated in ADAAG and ADA/ABAAG is a maximum slope for ramps, not a design requirement.... 
- 
    
  
  2 [§§ 4.7.2; 4.8.2; 4.1.6(3)(a)]
  2 [§§ 4.7.2; 4.8.2; 4.1.6(3)(a)] The running slope of the curb ramp is the slope in the direction that people travel when going up or down the ramp run.... 
- 
    
  
  1009.3.3 Handrails
  At least two handrails complying with 505 shall be provided on the sloped entry.... 
- 
    
  
  Performance and the Surface Deficiency Score
  A digital level and tape measure were used to identify instances along the accessible routes and at clear floor spaces where the surface running slope exceeded 1:16 (6.25%); the cross slope... 
- 
    
  
  M303.2.5 Surfaces
  Wheelchair space surfaces shall not slope more than 1:48 in any direction.... 
- 
    
  
  M303.2.5 Surfaces
  Wheelchair space surfaces shall not slope more than 1:48 in any direction.... 
- 
    
  
  5.8.1.2.1 Ramped Entry Slope
  5.8.1.2.1 Ramped Entry Slope.... 
- 
    
  
  Handrails
  Handrails Sloped entries must have handrails on both sides regardless of the slope. Handrail extensions are required at the top landing but not at the bottom.... 
- 
    
  
  Re: When is a Curb Ramp a Ramp?
  As for the image in the photo, it looks like a great candidate for a sloped walk (since a 5' long top landing and 6' long bottom landing are not required with a sloped walk, they are shorter... 
- 
    
  
  6.2.1 Circulation Routes Constructed at Beaches
  Beach access routes shall be provided where circulation routes such as boardwalks, walkways, or dune crossings are constructed along or across developed beach sites to provide pedestrian... 
- 
    
  
  M303.2.5 Surfaces (Section-by-Section Analysis)
  The MDE NPRM proposed to require diagnostic equipment used by patients seated in a wheelchair to provide a wheelchair space with a surface that does not slope more than 1:48 in any direction... 
- 
    
  
  11B-404.2.4.4 Floor or ground surface
  Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exceptions: Reserved.... 
- 
    
  
  Providing Appropriate Information About Accessibility
  For instance, include minimum width, maximum slope, and condition of the tread surface (is it firm and stable?) on information about trails.... 
- Figure 505.7.2 Handrail Non-Circular Cross Section – Drawing from the U.S. Access Board
- 
    
  
  F248.2 Minimum Number
  Pedestrian access points to a beach include parking facilities that serve beaches, dune crossings, and stairways or ramps leading from boardwalks to the beach.... 
- 
    
  
  4. Assess During the Planning, Installation and Maintenance Phases
  A digital level can be used to measure the running slope and cross slope.... 
- 
    
  
  1132A.4, Item 5
  In buildings containing covered multifamily dwelling units, the floor or landing immediately outside the entry may be sloped up to ¼ inch (6.35 mm) per foot (12 inches) (305 mm), in a direction... 
- 
    
  
  1132A.4, Item 5
  In buildings containing covered multifamily dwelling units, the floor or landing immediately outside the entry may be sloped up to ¼ inch (6.35 mm) per foot (12 inches) (305 mm), in a direction... 
- 
    
  
  Running Slope of Ramps Deployed to Roadways or Curb-Height Bus Stops
  See 36 CFR 1192.23(c)((5) (ramp slope requirements for buses and vans), 1192.159(c)(5) (OTRB-related ramp slope requirements).... 
- 
    
  
  5.8.1.2.1 Ramped Entry Slope Recommendations
  5.8.1.2.1 Ramped Entry Slope Recommendations The Committee recommends that raised platforms have a ramp with slopes that do not exceed the following: At 0 to 1½ inches, the slope... 
- 
    
  
  1134A.6, Item 2
  Slope. The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain.... 
- 
    
  
  1134A.6, Item 2
  Slope. The maximum slope of the shower floor shall be ½ inch (12.7 mm) per foot in any direction and shall slope to a drain.... 
- 
    
  
  11B-406.5.10 Diagonal curb ramps
  Diagonal curb ramps with flared sides shall have a segment of curb 24 inches (610 mm) long minimum located on each side of the curb ramp and within the marked crossing.... 