part is located 10 inches (255 mm) or less beyond the vertical reference plane, the operable part shall be 48 inches (1220 mm) high maximum and 15 inches (380 mm) high minimum above the floor...
Search Results "Extended Floor Surface"
Commonly Searched Documents
-
407.12.2.1 Unobstructed Side Reach
-
Flush Controls [4.18.4]
Flush Controls [4.18.4] Flush controls must be mounted no more than 44 inches above the finished floor and must: be automatic or operable by one hand operate without...
-
6.3(4)
(4) Each four-bed room shall have a minimum clear floor space of 48 in (1220 mm) from the foot of the bed to the foot of the opposing bed; 36 in (915 mm) between the side of the bed and...
-
11B-411.2.1.3.1 Keypad call console arrangement
The accessibility function button shall be located directly below the keypad at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....
-
11B-411.2.1.3.2 Touch screen call console arrangement
The accessibility function button shall be located at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....
-
1132A.4, Item 5
In buildings containing covered multifamily dwelling units, the floor or landing immediately outside the entry may be sloped up to ¼ inch (6.35 mm) per foot (12 inches) (305 mm), in a direction...
-
11B-203.13 Raised boxing or wrestling rings
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
§ 38.73(d)(3) Exception
Retrofitted vehicles shall be coordinated with the platform in new and key stations such that the horizontal gap shall be no greater than 4 inches and the height of the vehicle floor, under...
-
11B-411.2.1.3.2 Touch screen call console arrangement
The accessibility function button shall be located at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....
-
11B-411.2.1.3.1 Keypad call console arrangement
The accessibility function button shall be located directly below the keypad at a height of 36 inches (914 mm) to 42 inches (1067 mm) above the finish floor....
-
11B-203.13 Raised boxing or wrestling rings
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
- Hussey Seating Company Roll-A-Way Seating
-
Expert Report of Ken Schoonover, P.E., KMS Associates, Inc. (August 7, 2018)
entrance to the voting area contains a counter and two drinking fountains that protrude more than 4 inches into the route and the bottom of each object is more than 27 inches above the floor...
- Welch Allyn Scale-Tronix® Integrated Scales
-
11B-203.14 Raised diving boards and diving platforms
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...
-
1133A.2, Item 2
A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or forward approach shall be provided at the kitchen sink and all other fixtures or appliances...
-
1132A.10 Door signal devices
The activating mechanism shall be mounted a maximum of 48 inches (1219 mm) above the floor and connected to permanent wiring....
-
5.8.3.1 Breast Platform Height
The height of the top of the breast platform should be decreased to 26 inches above the floor....
-
11B-608.6 Shower spray unit and water
error by limiting the types of facilities that are allowed to use the vandalism prone area exception and requiring one of the two shower heads to be a maximum of 48 inches above the finish floor...
-
E. Grab Bars
Does each accessible toilet have a horizontal grab bar on the adjacent side wall that is at least 40" long and between 33"-36" above the floor for stabilization and assistance during transfer...
-
F. Grab Bars
Does each accessible toilet have a horizontal grab bar on the wall behind the toilet that is at least 36" long and between 33"-36" above the floor for stabilization and assistance during...
-
308.2.1 Unobstructed
Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or...
-
306.3.4 Clearance Reduction
Between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for each 6 inches...
-
803.5 Coat Hooks and Shelves
Shelves shall be 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....