Alterations or additions involving primary function areas must include an accessible path of travel that extends to site arrival points to the extent that the cost is not “disproportionate...
Search Results "Extended Floor Surface"
-
Alterations and Additions [§206.2.3.1, §202.4]
-
11B-504.5 Nosings
The permitted projection of the nosing shall extend 1¼ inches (32 mm) maximum over the tread below....
-
11B-504.5 Nosings
The permitted projection of the nosing shall extend 1¼ inches (32 mm) maximum over the tread below....
-
11B-1009.2.7 Operation
It is extremely important for a person who is swimming alone to be able to call the pool lift when it is in the up position so he or she will not be stranded in the water for extended periods...
-
1009.5.7 Grab Bars
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (100 mm) minimum and 6 inches (150 mm) maximum above each step and transfer platform....
-
1016.5 Obstacles
EXCEPTION: Where the surface is other than asphalt, concrete, or boards, obstacles shall be permitted to not exceed 1 inch (25 mm) in height measured vertically to the highest point....
-
Finish and Contrast [4.30.5]
Consideration should also be given to light sources and the ambient lighting to prevent glare on sign surfaces....
-
Roughness Measurement
The surface profiles were measured with a custom-built pathway measurement tool (PathMeT), which was created from a power WC frame that was instrumented with a wheel encoder and an Acuity...
-
1016.5 Obstacles
EXCEPTION: Where the surface is other than asphalt, concrete, or boards, obstacles shall be permitted to not exceed 1 inch (25 mm) in height measured vertically to the highest point....
-
M102.1 Defined Terms
The following terms are defined in the proposed standards: Enforcing authority, medical diagnostic equipment, operable parts, and transfer surface....
-
Section 35.151(i) Curb ramps (Section-by-Section Analysis)
Upon further consideration, however, the Department has concluded that the regulation should acknowledge that there are times when there are transitions from sidewalk to road surface that...
-
11B-1009.5.7 Grab bars
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (102 mm) minimum and 6 inches (152 mm) maximum above each step and transfer platform....
-
§ 38.159(c)(8) Handrails
grasp them from outside the vehicle while starting to board, and to continue to use them throughout the boarding process, and shall have the top between 30 inches (760 mm) above the ramp surface...
-
11B-1009.5.7 Grab bars
Where a grab bar is provided on each step, the tops of gripping surfaces shall be 4 inches (102 mm) minimum and 6 inches (152 mm) maximum above each step and transfer platform....
-
11B-705.1.1.2 Dome spacing
Truncated domes in a detectable warning surface shall have a center-to-center spacing of 2.3 inches (58 mm) minimum and 2.4 inches (61 mm) maximum, and a base-to-base spacing of 0.65 inch...
-
T405.3 Visual Contrast
The stripe shall be 1 inch (25 mm) wide minimum and shall contrast visually with the rest of the step tread or circulation path surface either light-on-dark or dark-on-light....
-
R405.3.4 Clearance Reduction
Between 230 mm (9 in) and 685 mm (2.25 ft) above the finish surface, the knee clearance shall be permitted to reduce at a rate of 25 mm (1 in) in depth for each 150 mm (6 in) in height....
-
6.10 Openings
Openings in the surface of beach access routes and their related resting intervals may be up to 1/2 inch (13 millimeters) wide....
-
§8.25(c) Existing public housing and multi-family Indian housing—needs assessment and transition plan
The Assistant Secretary for Fair Housing and Equal Opportunity and the Assistant Secretary for Public and Indian Housing may extend the four year period for a period not to exceed two years...
-
11B-307.4 Vertical clearance
The leading edge of such guardrail or barrier shall be located 27 inches (686 mm) maximum above the finish floor or ground....
-
§ 37.42(f)
platform design in which the horizontal gap between a car at rest and the platform is no more than 10 inches on tangent track and 13 inches on curves and the vertical height of the car floor...
-
9.2.2(7) Kitchens, Kitchenettes, or Wet Bars
Clear floor space for a front or parallel approach to cabinets, counters, sinks, and appliances shall be provided to comply with 4.2.4....
-
§ 37.42(f)
platform design in which the horizontal gap between a car at rest and the platform is no more than 10 inches on tangent track and 13 inches on curves and the vertical height of the car floor...
-
11B-307.4 Vertical clearance
The leading edge of such guardrail or barrier shall be located 27 inches (686 mm) maximum above the finish floor or ground....